Guides / RV solar panels for a camper van: how much solar you need
RV solar panels for a camper van: how much solar you need
The short answer
Enough panel to refill your daily use in the worst month you travel. PVWatts shows 100 W flat on a van roof making about 195 Wh a day in Denver in December and 571 Wh in June, so 1,200 Wh a day takes about 616 W in winter and 210 W in summer. Bring the cable in through one sealed entry, and fuse it.
Last updated 24 November 2026
Key takeaways
- Size solar to your daily watt-hours and the worst month you travel, not to the roof.
- Flat on a van roof, 100 W of panels makes about 634 Wh a day in Phoenix in June and 67 Wh in Seattle in December (PVWatts).
- Two 200 W rigid panels in series (73 V open circuit) suit a 100 V MPPT controller; three would exceed it.
- A Victron MPPT 100/30 handles 440 W of panels on 12 V and wants a 35 to 40 A battery fuse.
- Flexible panels are lighter, but Renogy's carries a 5-year output warranty against 25 years on its rigid panel.
This guide sizes, places and wires the panels. The rest of the system is in how to wire a camper van; driving charge is in DC to DC chargers.
How much will a panel produce per day where you travel?
From under 70 Wh to over 600 Wh a day per 100 W, depending on where and when. PVWatts, for panels flat on a roof, gives 634 Wh a day per 100 W in Phoenix in June and 67 Wh in Seattle in December.12
Source: PVWatts version 8 runs, 24 November 2026; 1 kW, tilt 0, fixed roof mount, 14% losses, DC output, scaled to 100 W. Chart ours.12
| Place | December | June | Year average |
|---|---|---|---|
| Phoenix, AZ | 261 Wh | 634 Wh | 445 Wh |
| San Diego, CA | 248 Wh | 593 Wh | 430 Wh |
| Austin, TX | 240 Wh | 523 Wh | 389 Wh |
| Denver, CO | 195 Wh | 571 Wh | 393 Wh |
| Asheville, NC | 193 Wh | 492 Wh | 359 Wh |
| Portland, ME | 125 Wh | 482 Wh | 323 Wh |
| Bozeman, MT | 87 Wh | 503 Wh | 310 Wh |
| Seattle, WA | 67 Wh | 457 Wh | 275 Wh |
These are our runs of PVWatts, the Department of Energy lab's solar model, with the panels lying flat as they do on most van roofs and the model's default 14% system losses.1 We used the DC output, since a van's panels charge a battery rather than feed an inverter, and PVWatts version 8 uses 2020 typical-year weather from the lab's National Solar Radiation Database.2 For a different place, run PVWatts with tilt 0 and read the monthly DC figure.
How much solar do you need on a camper van?
Daily watt-hours divided by the output per 100 W in your worst month, times 100. For 1,200 Wh a day, the PVWatts figures give about 210 W in Denver in June but about 616 W in December, so plan for the season you actually travel.1
1,200 Wh a day is an example load, not a recommendation; computed from the PVWatts figures in the table above. Chart ours.1
Get the daily watt-hours from a load list: each device's watts times hours a day, added up. The full worksheet is in the electrical system guide. Seattle in December shows why many vans pair solar with alternator charging: no roof holds the watts it would take. Also check the battery side: Battle Born's 100 Ah battery takes up to 50 A of charge, so a big array on a small bank is capped by the battery.10
How many watts fit on a Sprinter, Transit or ProMaster roof?
Measure your roof or rack, then divide by the panel's dimensions. On Orion Van Gear's Sprinter rack (53.875 in usable width, 139 to 195 in long), Renogy's 200 W rigid panel fits crossways 4 to 6 times: 800 to 1,200 W before fans and gaps.83
Our drawing, to scale lengthwise, from Orion Van Gear's rack FAQ and Renogy's panel specifications.83
| Rack length | Panels | Watts | Length left over |
|---|---|---|---|
| 139 in | 4 | 800 W | 18.7 in |
| 195 in | 6 | 1,200 W | 14.5 in |
The rack's length depends on the van model and wheelbase; Orion Van Gear lists racks for the 144 in and 170 in Sprinter and for 136 in and 159 in ProMasters, with about 4 in of clearance from roof to crossbar for a low-profile fan underneath.8 We could not find a Transit roof dimension or rack from a maker in our directory to use here, so measure your own roof, or your rack maker's drawing, the same way. Racks and panels from verified makers: Orion Van Gear for racks, Tectonic Overland for solar mounts; Renogy, Rich Solar, Go Power, Battle Born and REDARC for panels.
Rigid or flexible panels?
Rigid for a rack and a long life, flexible for a curved roof or a tight weight budget. Renogy's 200 W flexible panel weighs half as much as rigid ones by its own figure, but carries a 5-year output warranty against 25 years on its 200 W rigid panel.43
| Spec | Renogy 200 W rigid (ShadowFlux N-Type) | Renogy 200 W flexible |
|---|---|---|
| Size | 49.69 x 30.08 x 1.18 in3 | 63.2 x 29.4 x 0.1 in4 |
| Weight | 23.83 lb3 | "50% lighter than rigid panels" (Renogy)4 |
| Open circuit voltage | 36.5 V3 | 23.9 V4 |
| Operating voltage and current | 31.3 V, 6.38 A3 | 20.1 V, 10.02 A4 |
| Output warranty | 25 years, 80% output3 | 5 years, 90% output4 |
| Shape | Glass, most often with a metal frame4 | Bends up to 240°4 |
Renogy describes rigid panels as encased in glass, most often with a metal frame, and flexible ones as thin, light and able to follow the contour of a curved roof.4 Note the flexible panel is longer: at 63.2 in it does not fit crossways on a 53.875 in rack.48
How do you wire the panels to the controller?
Through a fuse or breaker and a disconnect to an MPPT controller, never straight to the battery. Keep the array's open circuit voltage under the controller's limit, with margin for cold, and at least 5 V above the battery voltage.75
Our diagram; negatives omitted for clarity. Rules from Victron's MPPT manual and Wiring Unlimited.57
Victron's SmartSolar MPPT 100/30 and 100/50 accept up to 100 V open circuit from the array, need the nominal array voltage at least 5 V above the battery, and warn that open circuit voltage is higher below 25 °C, so check the panel's temperature coefficient before adding panels in series.5 With Renogy's 36.5 V rigid panel, two in series make 73 V; three would be 109.5 V, over the limit before any cold correction, so a third panel goes in parallel instead.35 Renogy lists that panel's maximum series fuse as 15 A.3
Controller size follows the array. Victron rates the 100/30 for 440 W of panels on a 12 V battery and 880 W on 24 V, and the 100/50 for 700 W and 1,400 W; with more panels it limits input power.6 On the battery side the 100/30 wants a 35 to 40 A fuse and the 100/50 a 55 to 70 A fuse.5 Victron's wiring book adds that a fuse belongs between the array and the solar charger, subject to local rules, and the MPPT manual asks for a means to disconnect every current-carrying array conductor.75 Cable sizes come from the wire size calculator.
How do you mount panels and route the cable through the roof?
Rigid panels bolt to a rack or brackets; flexible ones bond to the roof. Bring every cable in through one sealed cable entry housing, a grommet sized to each cable and blanks in spare holes, and follow the roof and housing makers' sealing instructions.9
Orion Van Gear's five-port entry housing needs one rectangular cutout rather than several holes; it says to use the right grommet for each cable diameter, close unused positions with blank inserts, and, before cutting or drilling, check roof curvature, panel thickness, water drainage and the manufacturer's sealing requirements.9 Use outdoor solar cable: Victron describes it as UV and age resistant with tinned copper strands, usually with MC4 connectors that take 4 or 6 mm² cable.7 Victron also says the panel frames, not the array's positive or negative, should be grounded, with a single system ground near the battery.5
Every hole in the roof is a leak waiting for a bad bead. If you are not confident cutting the roof, a van shop can do that one step; look for one among our builders, or for a rack system among kit makers. More DIY steps are on the DIY hub, and every solar maker is in parts.
Questions people ask
How much solar do I need for a camper van?
Enough to refill your daily use in the worst month you travel. Divide your daily watt-hours by what 100 W of panels makes per day there, then multiply by 100. At 1,200 Wh a day, PVWatts figures for a flat roof give about 210 W in Denver in June but about 616 W in December.
How many watts does a 100 watt solar panel produce per day?
It depends on place and month. PVWatts, for 100 W of panels flat on a roof, gives about 634 Wh a day in Phoenix in June and 67 Wh a day in Seattle in December, a tenfold spread. Averaged over the year it ranges from about 275 Wh in Seattle to 445 Wh in Phoenix.
How many solar panels fit on a Sprinter roof?
On Orion Van Gear's Sprinter rack, with 53.875 in of usable width and 139 to 195 in of length, Renogy's 200 W rigid panel (49.69 x 30.08 in) fits crossways four to six times, 800 to 1,200 W at most. Fans, a hatch and gaps between panels take that down.
Are flexible solar panels good for vans?
They are lighter and follow a curved roof: Renogy says its 200 W flexible panel weighs 50% less than rigid panels and bends up to 240 degrees. The trade is warranty: 5 years at 90% output on that flexible panel against 25 years at 80% on its 200 W rigid panel.
Should van solar panels be wired in series or parallel?
Whatever keeps the array's open circuit voltage under the controller's limit with room for cold weather, and above the battery voltage plus 5 V. Two of Renogy's 36.5 V rigid panels in series make 73 V, inside a 100 V Victron MPPT; three would be 109.5 V, over it.
What size charge controller for 400 watts of solar?
Victron rates its SmartSolar MPPT 100/30 for 440 W of panels on a 12 V battery and the 100/50 for 700 W. So 400 W fits the 100/30 on 12 V. The controller limits input power if you connect more.
Do I need a fuse between solar panels and the charge controller?
Victron's wiring book says a fuse needs to be located between the array and the solar charger, and to check local rules. Its MPPT manual also asks for a means to disconnect all current-carrying conductors of the array, and a 35 to 40 A battery-side fuse for the 100/30.
How do you get solar cables through a van roof without leaks?
Use a single cable entry housing with a grommet sized for each cable and blanks in unused holes, and follow the housing and roof makers' sealing instructions. Orion Van Gear says to check roof curvature, panel thickness and drainage before cutting.
Sources
Daily output is computed from PVWatts version 8 (National Laboratory of the Rockies, formerly NREL) for 1 kW of standard panels mounted flat (tilt 0, fixed roof mount) with 14% system losses, using the DC monthly output and scaled to 100 W. Panel, rack and controller numbers are from the makers' own pages and manuals. All read or run 24 November 2026.
- PVWatts Calculator, US Department of Energy, National Laboratory of the Rockies (formerly NREL). Read 24 November 2026. Our runs used the PVWatts version 8 API, details below
- PVWatts version 8 API documentation (inputs, dc_monthly output, 2020 TMY weather data). Read 24 November 2026
- Renogy, 200W ShadowFlux N-Type solar panel, product specifications. Read 24 November 2026
- Renogy, 200 Watt 12 Volt flexible monocrystalline solar panel, product specifications. Read 24 November 2026
- Victron Energy, SmartSolar MPPT 100/30 and 100/50 manual, Installation (battery fuse, PV array limits, grounding). Read 24 November 2026
- Victron Energy, SmartSolar MPPT 100/30 and 100/50 manual, Technical specifications. Read 24 November 2026
- Victron Energy, Wiring Unlimited, chapter 4: DC wiring, section 4.12 Solar. Read 24 November 2026
- Orion Van Gear, Mercedes Sprinter Stealth roof rack, product page and FAQ. Read 24 November 2026
- Orion Van Gear, icotek KEL-FG-ER E5 cable entry housing kit, product page. Read 24 November 2026
- Battle Born Batteries, BB10012 100Ah 12V LiFePO4 battery manual (revision 038, 12 August 2026). Read 24 November 2026