Guides / Wire gauge chart and wire size calculator for 12V and 24V vans
Wire gauge chart and wire size calculator for 12V and 24V vans
The short answer
Pick the wire by two checks and keep the thicker result: voltage drop (circular mils = 10.75 x amps x round trip feet / allowed drop volts) and ampacity (the wire's current rating). For 20 A, 10 ft one way at 12 V and 3% drop, that is 8 AWG. The calculator below does both.
Last updated 24 November 2026
Key takeaways
- Size every DC wire twice, once for voltage drop and once for ampacity, and use the thicker answer.
- Voltage drop: circular mils = 10.75 x amps x round trip feet / allowed drop in volts (Ancor's published formula).
- Use 3% drop for charging, inverter, fridge and electronics circuits and 10% only for non-critical loads like lighting.
- 12 AWG copper rated 105 °C carries 45 A outside an engine space; the same gauge rated 60 °C carries 25 A (33 CFR 183.425).
- The fuse must not be bigger than the wire's rating, and a manual's cable size wins when it asks for thicker wire.
This is the wire chart and calculator for 12 V and 24 V van circuits, with the formula and the tables behind every number on the page. It does not cover 120 V AC wiring; hire a licensed electrician for that.
Wire size calculator (12 V and 24 V DC)
Enter the current and the one-way distance from the power source to the load. The calculator doubles the length for the return wire.
Minimum: 8 AWG copper
- Voltage drop: needs 11,944 circular mils (10.75 x 20 A x 20 ft round trip / 0.36 V), so 8 AWG (16,800 CM).
- Ampacity: 16 AWG is the smallest 105 °C wire rated for 20 A or more (25 A).
- Voltage drop sets the size on this circuit, not ampacity. The fuse protecting this wire must not be rated above the wire's 80 A.
Stranded copper only, 16 AWG or larger. Not derated for engine spaces or bundles; size up if the run is hot or bundled. A manufacturer's manual that names a cable size overrides this result when it asks for thicker wire.
How it works: circular mils needed = 10.75 x I x 2L / (drop x system volts), where 10.75 is Ancor's constant for copper, I is amps and L is one-way feet.1 The result is the first AWG in Ancor's circular mil column at or above that figure; the calculator then checks ampacity in the Coast Guard's Table 5 for the insulation rating you choose and keeps the thicker wire. It never goes below 16 AWG, the smallest conductor the same Coast Guard rule allows when installed on its own (18 AWG only inside a multiconductor sheath).35 We tested it against Ancor's own worked example (10 A, 21 ft round trip, 3% at 12 V gives 6,271 CM and 12 AWG) and against cells of Ancor's printed tables.12
How do you size wire for current and voltage drop?
Run two checks. Voltage drop: compute circular mils from current, round trip length and allowed drop, and take the next AWG up. Ampacity: the wire's rating must be at least the current. Use whichever wire is thicker.13
Ancor's catalog gives the voltage drop formula as CM = K x I x L / E, with K = 10.75 for copper, I the current in amps, L the length in feet from the positive source connection to the device and back to the negative, and E the allowed drop in volts. It adds that the NFPA and the Coast Guard require the next larger conductor when the result falls between two sizes.1 Its own example: a 10 A bilge pump with an 11 ft positive and a 10 ft negative run, sized for 3% at 12 V (0.36 V), needs 10.75 x 10 x 21 / 0.36 = 6,271 circular mils, so 12 AWG at 6,500.2
The ampacity check is about heat. The Coast Guard rule for boats says that, except for intermittent surges, a conductor must not carry more current than Table 5 allows for its gauge and insulation temperature rating.5 No federal rule sets a DC wire table for vans, so this guide uses that table, the one Ancor reprints for its own wire.3
3% or 10% voltage drop: which circuits get which?
3% for anything where low voltage causes trouble: main feeders, charging, inverter, fridge, electronics. 10% only for non-critical loads such as general lighting. That split is ABYC E-11's, as Ancor quotes it.12
Ancor quotes ABYC E-11 section 11.16.1.2.7: panelboard or switchboard main feeders, bilge blowers, electronic equipment, navigation lights and other circuits where voltage drop must be kept to a minimum are sized for no more than 3%; lighting other than navigation lights, and other circuits where drop is not critical, for no more than 10%.12 Victron, writing about battery, charger and inverter cables, advises aiming for no more than 2.5%, which is 0.3 V at 12 V and 0.6 V at 24 V.7 If you want a margin, size those heavy cables tighter than 3%.
Lost voltage is lost energy and heat. Victron's example is a 2,400 W inverter on two 1.5 m, 16 mm² cables: 200 A at 12 V drops 0.64 V, about 5% of the energy, and the same cables at 24 V drop 1.3%.7
What is the ampacity of each AWG size?
It depends on the insulation's temperature rating. The Coast Guard's Table 5 gives, for example, 12 AWG 45 A, 10 AWG 60 A, 8 AWG 80 A and 4 AWG 160 A for 105 °C wire outside an engine space, and much less for 60 °C wire.5
This is the wire gauge chart to copy. Circular mil areas are Ancor's, for its AWG boat cable and for SAE automotive wire of the same gauge number.3 Ampacities outside an engine space are from 33 CFR 183.425 Table 5.5 The engine space column is Ancor's, already derated by 0.85 for 105 °C wire.3 Ancor lists no 3 AWG row, so it is left out here.
| AWG | CM (AWG) | CM (SAE) | 60 °C | 75 °C | 90 °C | 105 °C | 105 °C engine space |
|---|---|---|---|---|---|---|---|
| 18 | 1,600 | 1,537 | 10 A | 10 A | 20 A | 20 A | 17 A |
| 16 | 2,600 | 2,336 | 15 A | 15 A | 25 A | 25 A | 21 A |
| 14 | 4,100 | 3,702 | 20 A | 20 A | 30 A | 35 A | 30 A |
| 12 | 6,500 | 5,833 | 25 A | 25 A | 40 A | 45 A | 38 A |
| 10 | 10,500 | 9,343 | 40 A | 40 A | 55 A | 60 A | 51 A |
| 8 | 16,800 | 14,810 | 55 A | 65 A | 70 A | 80 A | 68 A |
| 6 | 26,600 | 24,538 | 80 A | 95 A | 100 A | 120 A | 102 A |
| 4 | 42,000 | 37,360 | 105 A | 125 A | 135 A | 160 A | 136 A |
| 2 | 66,500 | 62,450 | 140 A | 170 A | 180 A | 210 A | 178 A |
| 1 | 83,690 | 77,790 | 165 A | 195 A | 210 A | 245 A | 208 A |
| 1/0 | 105,600 | 98,980 | 195 A | 230 A | 245 A | 285 A | 242 A |
| 2/0 | 133,100 | 125,100 | 225 A | 265 A | 285 A | 330 A | 280 A |
| 3/0 | 167,800 | 158,600 | 260 A | 310 A | 330 A | 385 A | 327 A |
| 4/0 | 211,600 | 205,500 | 300 A | 360 A | 385 A | 445 A | 378 A |
Source: US Coast Guard, 33 CFR 183.425 Table 5, read 24 November 2026; chart ours.5
Two corrections lower these numbers. In an engine space, multiply by the factor for the insulation rating (0.85 for 105 °C, 0.58 for 60 °C); and when three or more current-carrying conductors are bundled, multiply by 0.70 for three, 0.60 for four to six, 0.50 for seven to 24 and 0.40 for 25 or more.5 Ancor applies the bundle factors to circuits of 50 V or more and says voltage drop is the controlling factor below 50 V.4 Our calculator does not derate; if a cable runs through the engine bay or in a tight bundle, go up a size.
How does length affect wire size?
Directly: the circular mils needed rise in proportion to the round trip length. At 20 A and 12 V with 3% drop, 5 ft one way needs 12 AWG and 25 ft needs 4 AWG, while ampacity alone would allow 16 AWG.15
Computed from CM = 10.75 x I x 2L / E (Ancor) and Ancor's AWG circular mil areas; chart ours.13
That is why the batteries, inverter and charger should sit close together. Victron's book says to keep high-current cables as short as possible so they do not need to be very thick, and to let cables shed heat: a 2.5% drop on a 1,000 W load is 25 W of heat in the cable.6
What size wire for common van circuits?
Read it off the tables below by current and one-way length, or use the calculator. A star marks cells where ampacity, not voltage drop, sets the size. Where a component manual names a cable size, use the manual's size if it is thicker.1356
| Amps | 3 ft | 5 ft | 10 ft | 15 ft | 20 ft | 25 ft |
|---|---|---|---|---|---|---|
| 5 A | 16 | 16 | 14 | 12 | 12 | 10 |
| 10 A | 16 | 14 | 12 | 10 | 8 | 8 |
| 15 A | 14 | 12 | 10 | 8 | 6 | 6 |
| 20 A | 14 | 12 | 8 | 6 | 6 | 4 |
| 25 A | 12 | 10 | 8 | 6 | 4 | 4 |
| 30 A | 12 | 10 | 6 | 4 | 4 | 2 |
| 40 A | 10 | 8 | 6 | 4 | 2 | 2 |
| 50 A | 10 | 8 | 4 | 2 | 2 | 1 |
| 60 A | 8 | 6 | 4 | 2 | 1 | 1/0 |
| 80 A | 8 | 6 | 2 | 1 | 1/0 | 2/0 |
| 100 A | 6 | 4 | 2 | 1/0 | 2/0 | 3/0 |
| 150 A | 4 | 2 | 1/0 | 3/0 | 4/0 | 4/0+ |
Show the 24 V, 3% table
| Amps | 3 ft | 5 ft | 10 ft | 15 ft | 20 ft | 25 ft |
|---|---|---|---|---|---|---|
| 5 A | 16 | 16 | 16 | 16 | 14 | 14 |
| 10 A | 16 | 16 | 14 | 12 | 12 | 10 |
| 15 A | 16 | 16 | 12 | 10 | 10 | 8 |
| 20 A | 16 | 14 | 12 | 10 | 8 | 8 |
| 25 A | 16 | 14 | 10 | 8 | 8 | 6 |
| 30 A | 14 | 12 | 10 | 8 | 6 | 6 |
| 40 A | 12* | 12 | 8 | 6 | 6 | 4 |
| 50 A | 10* | 10 | 8 | 6 | 4 | 4 |
| 60 A | 10* | 10 | 6 | 4 | 4 | 2 |
| 80 A | 8* | 8 | 6 | 4 | 2 | 2 |
| 100 A | 6* | 6* | 4 | 2 | 2 | 1 |
| 150 A | 4* | 4* | 2 | 1 | 1/0 | 2/0 |
Show the 12 V, 10% table (non-critical loads only)
| Amps | 3 ft | 5 ft | 10 ft | 15 ft | 20 ft | 25 ft |
|---|---|---|---|---|---|---|
| 5 A | 16 | 16 | 16 | 16 | 16 | 16 |
| 10 A | 16 | 16 | 16 | 14 | 14 | 12 |
| 15 A | 16 | 16 | 14 | 14 | 12 | 10 |
| 20 A | 16 | 16 | 14 | 12 | 10 | 10 |
| 25 A | 16 | 16 | 12 | 10 | 10 | 8 |
| 30 A | 14* | 14 | 12 | 10 | 8 | 8 |
| 40 A | 12* | 12* | 10 | 8 | 8 | 6 |
| 50 A | 10* | 10* | 10 | 8 | 6 | 6 |
| 60 A | 10* | 10* | 8 | 8 | 6 | 4 |
| 80 A | 8* | 8* | 8 | 6 | 4 | 4 |
| 100 A | 6* | 6* | 6 | 4 | 4 | 2 |
| 150 A | 4* | 4* | 4 | 4 | 2 | 1 |
Victron's book makes the same point from the maker's side: all its manuals recommend the battery cable and fuse size for each product.6 Two examples: the Orion XS 50 A DC-DC charger asks for 6 AWG under 5 m and 4 AWG from 5 to 10 m, with a 60 to 70 A battery fuse,8 and REDARC's BCDC1240D and BCDC1250D ask for 6 AWG from 1 to 5 m and 4 AWG from 5 to 9 m.9 More on those runs in DC to DC chargers.
Marine tinned wire or automotive wire?
Size SAE automotive wire one gauge larger, because it has less copper than AWG wire of the same number: 12 SAE is 5,833 circular mils, 12 AWG is 6,500. Ancor's example says 10 SAE must be used where the math calls for 12 AWG.23
Insulation rating matters as much as copper: Ancor says all its boat cable is 105 °C insulated, and its ampacity tables apply only to 105 °C and other premium wire, not to lesser grades.4 Check the temperature rating printed on the jacket and pick that column in the chart. Victron recommends flexible, multi-stranded copper, and tinned strands for marine use and for solar cable.6
How do fuses relate to wire size?
The fuse protects the wire, so it can never be rated above the wire. Victron: with one device on a circuit, match the fuse to the device's current rating or the cable's, whichever is lower; with several devices, match it to the cable.6
Every positive wire that leaves a battery gets its own fuse, placed in the positive cable; a DC system usually has a main battery fuse and then an individual fuse for each consumer.6 With lithium batteries, at least one fuse in the line must also have an interrupt rating at least equal to the bank's maximum short circuit current, which Victron calls mandatory.6 How that fits into a whole build is in how to wire a camper van electrical system.
Where do you buy wire and parts?
From parts makers that publish their cable and fuse specs. Our parts directory lists verified makers, including Victron Energy, EXPLORIST.life and Vanlife Outfitters.
If you would rather buy the cabinetry and wire it yourself, see DIY kit makers. The rest of the electrical series: the whole system, solar panels and alternator charging. Every build topic is on the DIY hub, and the order of work is in DIY van build.
Questions people ask
What size wire do I need for 12 volts?
It depends on the current and the length. Work out the circular mils with CM = 10.75 x amps x round trip feet / allowed drop volts, pick the next AWG up, then check the wire's ampacity is at least the current. For 20 A over 10 ft one way at 3%, that is 8 AWG.
What gauge wire for a 30 amp DC-DC charger or solar controller?
Use the size in the product manual first. Victron's Orion XS manual asks for 6 AWG under 5 m and 4 AWG from 5 to 10 m for its 50 A charger; REDARC's BCDC manual gives 8 AWG or 6 AWG for its 25 A model depending on length. Use our calculator only when the manual is silent.
Should I use 3% or 10% voltage drop?
Ancor quotes ABYC E-11: 3% for main feeders, electronics and other circuits where drop must be kept to a minimum, 10% where drop is not critical, such as general lighting. In a van, size charging, inverter, fridge and electronics circuits at 3%.
Is marine wire better than automotive wire?
For sizing, yes: Ancor's chart shows automotive SAE wire of the same gauge number has less copper than AWG wire (12 SAE 5,833 circular mils against 12 AWG 6,500). Its worked example says to go up one size if you use SAE wire. Marine boat cable is also tinned and 105 °C rated.
How many amps can 10 gauge wire carry?
60 A for 105 °C insulation outside an engine space, 40 A for 60 °C insulation, per the US Coast Guard's Table 5 in 33 CFR 183.425. That is the heat limit; on a long 12 V run, voltage drop will ask for thicker wire well before 60 A.
Can I use a bigger fuse than the wire rating?
No. Victron's Wiring Unlimited says the fuse must match the current rating of the cable, or of the single device on the circuit if that is lower. A fuse bigger than the wire lets the wire overheat before the fuse opens.
Does 24 V need thinner wire than 12 V?
Yes, for the same power. Doubling the voltage halves the current, and the allowed drop in volts doubles, so the circular mils needed fall to a quarter. Victron's example shows a 2,400 W load dropping 5% at 12 V and 1.3% at 24 V on the same cables.
Should I hire an electrician for van wiring?
Hire one for anything 120 V, for the main battery and inverter cables if you are not sure of them, and whenever a manual and a chart disagree. Victron's own wiring book says electrical work should be carried out by a qualified electrician or technician, and REDARC recommends a suitably qualified installer for its chargers.
Sources
Sizes are computed at build time and in your browser from two published tables: Ancor's circular mil areas and voltage drop formula (Catalog 2024, pages 62 to 64) and the US Coast Guard's ampacity table in 33 CFR 183.425. ABYC E-11 itself was not opened; its 3% and 10% rules are cited as Ancor quotes them. Read 24 November 2026.
- Ancor (marine wire maker), Catalog 2024, page 62: conductors sized for 3% voltage drop, and the circular mil formula. Read 24 November 2026. Quotes ABYC E-11 section 11.16.1.2.7 on 3% circuits
- Ancor, Catalog 2024, page 63: conductors sized for 10% voltage drop, worked example, SAE vs AWG wire. Read 24 November 2026. Quotes ABYC E-11 section 11.16.1.2.7 on 10% circuits
- Ancor, Catalog 2024, page 64: temperature rating of conductor insulation; AWG and SAE circular mil areas; ampacity inside and outside engine spaces. Read 24 November 2026
- Ancor, Catalog 2024, page 65: allowable amperage of conductors of 50 volts or more (bundles). Read 24 November 2026
- US Coast Guard, 33 CFR 183.425, Conductors: General, Table 5 (eCFR, current). Read 24 November 2026. A rule for boats; vans have no federal DC wire table
- Victron Energy, Wiring Unlimited, chapter 4: DC wiring (cable selection, fuses, cable runs). Read 24 November 2026
- Victron Energy, Wiring Unlimited, chapter 2: Theory (voltage drop at 12, 24 and 48 V). Read 24 November 2026
- Victron Energy, Orion XS 12/12-50A DC-DC battery charger manual, Installation. Read 24 November 2026
- REDARC, BCDC Dual Input In-Vehicle Battery Charger instruction manual (linked from REDARC's US product page). Read 24 November 2026