Guides / Pure sine wave inverter for a van: what size inverter you need
Pure sine wave inverter for a van: what size inverter you need
The short answer
Add the watts of everything you will run at the same time and pick a pure sine wave inverter that covers it continuously at a warm cabin temperature, with surge for motors. Then the DC side decides the rest: a 2,000 W inverter draws about 196 A at 12 V and needs the battery, cable and Class T fuse its manual names.
Last updated 24 November 2026
Key takeaways
- Size a van inverter from the loads that run at the same time, using its continuous rating at a warm temperature: Victron's 12/1200 drops from 1,200 W at 25 °C to 1,100 W at 40 °C.
- Choose pure sine: Samlex lists devices with clocks, speed controls and transformer-less chargers that may misbehave or be damaged on modified sine.
- A 2,000 W inverter draws about 196 A at 12 V by Samlex's formula; Samlex's PST-2000-12 needs a 250 A Class T fuse within 7 in of the battery and 2 AWG to 4/0 cable.
- Idle draw adds up: 11 W for Victron's 12/1200 is about 22 Ah a day at 12 V; use ECO mode or switch it off.
- Have a licensed electrician do the 120 V side, including grounding and neutral bonding, which differ between inverter models.
The inverter is the biggest load in a van electrical system. Its battery is covered in lithium battery size, its fuse in fuse size.
Pure sine or modified sine?
Pure sine. Samlex explains that a modified sine wave jumps, pauses at zero and carries harmonics that heat motors and microwaves, and lists devices that may not work or may be damaged on it, from clocks and dimmers to induction cooktops and some battery chargers.1
| Device type | What may happen |
|---|---|
| Laser printers, photocopiers | May not work properly |
| Built-in clocks (microwaves, coffee makers, clock radios) | May not keep time |
| Dimmers, fan and motor speed controls, sewing machines with speed control | Dimming or speed control may not work |
| Transformer-less capacitive devices: some razors, flashlights, night lights, smoke detectors, power tool battery chargers | May be damaged |
| Induction cooktops; some fluorescent fixtures | May not work; inverter may shut down on overload |
| Motors, compressors, microwaves | Run hotter from harmonics |
Source: Samlex PST-1500 and PST-2000 manual, sections 2.2 to 2.4.1
How do you size an inverter from your loads?
Add the watts of loads that run at once, check the biggest motor start against the surge rating, and use the continuous rating at a warm temperature. Victron's 12/1600 120 V is rated 1,500 W at 25 °C and 1,350 W at 40 °C.6
| Step | What to do | Worked example (our inputs, not product data) |
|---|---|---|
| 1. Loads at once | List what runs at the same time, watts from each label. | Loads totalling 1,000 W |
| 2. Surge | Largest motor or compressor start must fit the surge or peak rating. | Check against the manual's peak figure |
| 3. Warm rating | Continuous output at 40 °C must cover step 1. | Victron 12/1200 120V: 1,100 W at 40 °C, passes6 |
| 4. DC current | Watts / (battery volts x efficiency). | 1,000 / (12 x 0.85) = 98 A1 |
| 5. Battery | Battery bank continuous rating at least step 4; follow the inverter's battery size. | One Battle Born BB10012 is rated 100 A continuous: just enough11 |
| 6. Cable and fuse | From the inverter manual's table for your cable length. | Victron 12/1200: 25 mm² up to 1.5 m, internal 200 A fuse, extra fuse near the battery over 1.5 m5 |
| 7. Idle draw | Zero-load watts x hours left on; add to the energy budget. | 11 W x 24 h = 264 Wh6 |
Sources: Victron Inverter VE.Direct 120V and Inverter Smart manuals, technical specifications, read 24 November 2026. The Inverter Smart is rated 2,000 and 3,000 VA; these are its watt figures. Chart ours.610
Peak ratings cover starts, not running loads: Victron lists 1,600 W for 15 seconds on the 12/1200 120V, and Samlex 3,500 W surge on the PST-2000 and 6,000 W on the PST-3000.624 Samlex rates its inverters with a resistive load at a power factor of 1 and an ambient of 25 °C.2
What battery and cable does a 2000W or 3000W inverter need?
By Samlex's formula a 2,000 W inverter draws about 196 A at 12 V and 3,000 W about 294 A. Samlex's PST-2000-12 needs a 250 A Class T fuse and 2 AWG to 4/0 cable by length; Victron recommends 350 to 1,000 Ah of battery for its 12/2000.18
Formula and efficiencies from Samlex PST manual section 8.4.3; the arithmetic is ours.1
| Inverter (12 V) | Continuous / peak | Fuse | Battery cable | Battery |
|---|---|---|---|---|
| Victron Inverter VE.Direct 12/1200 120V | 1,200 W / 1,600 W for 15 s6 | Internal 200 A MIDI; add a fuse close to the battery if the cable is over 1.5 m | 25 mm² to 1.5 m, 35 mm² to 3 m; terminal takes up to 2 AWG5 | Not given |
| Victron Inverter VE.Direct 12/1600 120V | 1,500 W / 2,100 W for 15 s6 | Internal 250 A MEGA; same rule over 1.5 m | 35 mm² to 1.5 m, 50 mm² to 3 m; terminal takes up to 1/0 AWG5 | Not given |
| Samlex PST-2000-12 | 2,000 W / 3,500 W surge; 240 A maximum input2 | 250 A, Class T or equivalent, within 7 in of the battery positive | 3 ft: 2 AWG (2% drop) or 3 AWG (3%); 6 ft: 2/0 or 1/0; 10 ft: 4/0 or 3/01 | Not given |
| Samlex PST-3000-12 | 3,000 W / 6,000 W surge; 360 A maximum input4 | Class T or equivalent within 7 in; no rating in its table | 3 ft: 1/0 (2%) or 2 AWG (3%); 6 ft: 4/0 or 2/0; 10 ft: two 2/0 or 4/03 | Not given |
| Victron Inverter Smart 12/2000 (230 V) | 1,600 W / 4,000 VA peak10 | 300 A external; no fuse inside | 70 mm² to 5 m; over 5 m not recommended8 | 350 to 1,000 Ah |
| Victron Inverter Smart 12/3000 (230 V) | 2,400 W / 6,000 VA peak10 | 400 A external; no fuse inside | 90 mm² to 5 m; two 70 mm² from 5 to 10 m8 | 400 to 1,200 Ah |
Battery current is the limit people miss. At 196 A, a bank of Battle Born BB10012s, each rated 100 A continuous, needs at least 2 in parallel; at 294 A, at least 3. That is arithmetic on the battery's rating, not a maker's recommendation. Battle Born also requires a current surge limiter with inverters of 3,500 W or more.11 Samlex notes that the NEC and UL 458 generally require conductors rated for at least 125% of the continuous DC input current, and that voltage drop, typically held to 2 to 3%, usually sets the size.1
The internal fuses do not protect the cable. Samlex says the fuses inside its inverters protect internal parts and will not blow for a short along the battery cables, so the external fuse is mandatory.1 On a lithium bank that external fuse also needs an interrupt rating covering the bank's short circuit current.12 Size the run with the wire size calculator and keep it short: Victron says mount the inverter as close as possible to the batteries.5
How much power does an inverter use when idle?
Enough to matter over a day. Victron lists 11 W with no load for its 12/1200 120V, about 22 Ah a day at 12 V, and Samlex under 1.0 A for the PST-2000-12. ECO or search mode cuts this to about 1 W on Victron's smaller models.62
Zero-load figures from Victron's Inverter VE.Direct 120V and Inverter Smart specifications and Samlex's PST-2000 and PST-3000 spec sheets (Samlex gives amps; we multiplied by 12 V); 24-hour arithmetic and chart ours.61024
Victron's ECO mode puts the inverter on standby when the load falls below a set level and checks every few seconds for a load, which it says reduces consumption by about 85%; the sensitivity is adjustable.9 If nothing needs 120 V, switch the inverter off. Victron's remote connector can tie the inverter to the ignition or to a lithium battery's BMS.8
Where does the inverter go, and who wires the 120 V side?
Close to the battery but never above it, dry, ventilated and away from fabrics. The 120 V side belongs to a licensed electrician: Victron and Samlex both call for a qualified or certified electrician, and grounding and neutral bonding differ between models.51
Our diagram of the rules in Victron's Inverter VE.Direct 120V and Inverter Smart manuals and Samlex's PST manual. Not a wiring diagram for the AC side.581
Location, from Victron: as close as possible to the batteries, never directly above them, in a dry, well ventilated place out of direct sun, with 10 cm clear around it, in a heat resistant spot with no textiles or chemicals nearby.5 The chassis ground conductor should be at least half the cross-section of the battery cables.58 Samlex says fit the external fuse last, after every other connection, so the spark from the input capacitors happens at the fuse.1
The AC side is where models differ, which is why it is a job for a licensed electrician. Victron's 120 V VE.Direct inverters have a floating output, except the GFCI model, and need a neutral to ground connection for a GFCI to work; local rules may require a true neutral.57 Samlex's PST bonds neutral to the chassis and has GFCI outlets, and warns that feeding it into a panel where neutral is bonded to ground will trip the GFCI.1 Victron says never connect the output to another AC source.5 RV standards such as the NEC's Article 551 and NFPA 1192 cover 120 V wiring in RVs; we could not open their text, so we do not paraphrase them.
Who makes inverters for vans?
Verified inverter makers in our directory include Victron Energy, Samlex America, KISAE Technology, Renogy and Go Power.
More are in our parts directory. The rest of the electrical series: the whole system, wire size, fuses, batteries, solar panels, charge controllers and DC-DC chargers. Every build topic is on the DIY hub.
Questions people ask
What size inverter do I need for a camper van?
One whose continuous rating at a warm cabin temperature covers everything you will run at the same time, and whose surge rating covers motor starts. Then check the battery and cables can carry its DC current: about 196 A at 12 V for 2,000 W, by Samlex's formula.
How many batteries do I need for a 2000W inverter?
Enough to supply about 196 A continuously at 12 V. Battle Born's BB10012 is rated 100 A continuous, so that is two in parallel at minimum by arithmetic. Victron recommends 350 to 1,000 Ah of battery for its 12/2000 Inverter Smart.
Is a modified sine wave inverter OK in a van?
For some loads, but Samlex lists many that may not work or may be damaged: devices with clocks or speed controls, laser printers, induction cooktops, and transformer-less chargers such as some razor and power tool chargers. A pure sine inverter avoids the problem.
Should I leave my inverter on all the time?
Not if you can avoid it. Victron's 12/1200 120 V inverter draws 11 W with no load, about 22 Ah a day at 12 V. Victron's ECO mode cuts idle draw by about 85% by standing by until a load appears; switch the inverter off when not needed.
What fuse does a 2000W inverter need?
The one its manual names. Samlex specifies a 250 A Class T or equivalent fuse within 7 in of the battery positive for its PST-2000-12; Victron specifies 300 A for its 12/2000 Inverter Smart. Internal inverter fuses do not protect the battery cables.
Can I plug the inverter's output into my van's shore power inlet or a wall outlet?
No. Victron says never connect an inverter's AC output to another AC source such as a household outlet or a generator. Switching between shore power and an inverter needs a transfer switch or an inverter charger, installed by a licensed electrician.
Do I need an electrician to install an inverter?
For the 120 V AC side, yes. Victron says its inverters should be installed by a qualified electrician, and Samlex that installation and wiring must comply with electrical codes and be done by a certified electrician. Grounding and neutral bonding differ between models.
Sources
Ratings, cable sizes, fuses and idle draw are from Samlex's PST manuals and spec sheets and Victron's Inverter VE.Direct 120V and Inverter Smart manuals; battery limits from Battle Born. DC current, battery count and amp-hour figures are our arithmetic, shown with the formula. Victron's Inverter Smart rows are its 230 V models, included for their DC data; the DC side depends on watts and battery voltage. KISAE's, Renogy's and Go Power's manuals could not be opened, so those makers are linked, not quoted. NEC and NFPA 1192 text could not be opened. All read 24 November 2026.
- Samlex America, PST-1500 and PST-2000 pure sine wave inverter owner's manual (document 11001, July 2026). Read 24 November 2026. Sections 1.2, 1.3.4, 2, 8.4 and 8.5
- Samlex America, PST-2000 specification sheet (12001-PST-2000-12-24-48-0826). Read 24 November 2026
- Samlex America, PST-3000 pure sine wave inverter owner's manual (document 11001, July 2026). Read 24 November 2026. Section 8.3, Table 8.3
- Samlex America, PST-3000 specification sheet (12001-PST-3000-12-24-48-0726). Read 24 November 2026
- Victron Energy, Inverter VE.Direct 120V manual, Installation. Read 24 November 2026
- Victron Energy, Inverter VE.Direct 120V manual, Technical specifications. Read 24 November 2026
- Victron Energy, Inverter VE.Direct 120V manual, Appendix (neutral to ground connection). Read 24 November 2026
- Victron Energy, Inverter Smart manual, Installation (230 V models: battery cable, fuse and battery size). Read 24 November 2026
- Victron Energy, Inverter Smart manual, General description (ECO mode). Read 24 November 2026
- Victron Energy, Inverter Smart manual, Technical specifications. Read 24 November 2026
- Battle Born Batteries, BB10012 100Ah 12V LiFePO4 battery manual (revision 038, 12 August 2026). Read 24 November 2026
- Victron Energy, Wiring Unlimited, chapter 4: DC wiring (fuses, interrupt rating, multiple inverters). Read 24 November 2026