LiFePO4 battery for a camper van: what size lithium battery you need
The short answer
Size it from your loads: add up each load's watts times hours a day, divide by 12 for amp-hours, and multiply by the days you want to go without charging. A LiFePO4 battery like Battle Born's can use 100% of its rating, so 1,200 Wh a day for two days needs 200 Ah. Lithium beats AGM on weight and cycles, but must not be charged below freezing unless it is heated.
Last updated 24 November 2026
Key takeaways
- Size the battery from your loads: daily watt-hours divided by battery voltage gives amp-hours a day, then multiply by the days you want without charging.
- 100 Ah at 12 V holds about 1,200 Wh; Battle Born rates its 100 Ah LiFePO4 battery for 100% usable depth of discharge and 3,000 to 5,000 cycles.
- A Victron AGM deep cycle battery is rated 600 cycles at 50% depth of discharge, and its 110 Ah model weighs 32 kg against 31 lb for Battle Born's 100 Ah.
- Most LiFePO4 batteries must not charge below freezing: Battle Born's BMS blocks charging under 32 °F; heated models warm the cells first.
- Secure the battery so it cannot shift, slide or tip, torque the terminals to the manual's figure, and fuse it at the terminal.
The battery is the centre of the system in how to wire a camper van; charge it from solar and a DC-DC charger, and fuse it with the fuse size guide.
How many amp hours do you need?
Daily watt-hours divided by battery voltage, times the days you want to go without charging. 1,200 Wh a day at 12 V is 100 Ah a day; for two days, 200 Ah. Use the usable depth of discharge your battery's maker states.1
Fill in the worksheet below with numbers from each appliance's label or manual. Count anything that runs all day, such as an inverter left on: Victron's 12/1200 120 V inverter draws 11 W with no load, which is 264 Wh over 24 hours.10
| Load | Watts (label or manual) | Hours a day | Wh a day (watts x hours) |
|---|---|---|---|
| Fridge (use its average draw) | |||
| Lights | |||
| Roof fan | |||
| Water pump | |||
| Phone and laptop charging | |||
| Diesel heater (12 V draw) | |||
| Inverter left on, no load (Victron 12/1200 example) | 11 | 24 | 264 |
| Total Wh a day | Add the last column | ||
| Amp-hours a day | Total Wh divided by 12 (or 24 for a 24 V bank) | ||
| Battery size | Amp-hours a day x days without charging, divided by usable depth of discharge (1.0 for Battle Born's rating) | ||
Arithmetic: Wh / V = Ah. We divide by 12 V, which slightly overstates amp-hours against a 12.8 V nominal LiFePO4 rating, the safe direction. Chart ours.
Charging limits the useful size too. Battle Born recommends charging at 0.5C, a maximum of 50 A per 100 Ah battery,1 while Renogy recommends 50 A and allows up to 100 A on its 100 Ah RBT12100LFP-H.3 A bank much bigger than your solar and alternator can refill only helps on long stretches without sun; see how much solar a van needs.
LiFePO4 or AGM?
LiFePO4 for most vans: more usable energy for the weight and many more cycles. Battle Born's 100 Ah weighs 31 lb and is rated 3,000 to 5,000 cycles; Victron's 110 Ah AGM weighs 32 kg and is rated 600 cycles at 50% depth of discharge.14
| Spec | Battle Born BB10012 (LiFePO4) | Renogy RBT12100LFP-H (LiFePO4, self-heating) | Victron AGM Deep Cycle 12 V 110 Ah |
|---|---|---|---|
| Weight | 31 lb1 | 21.38 lb3 | 32 kg (about 71 lb)4 |
| Usable depth of discharge | 100% | Cycle rating given at 80% | No limit stated; cycle life falls the deeper you go |
| Cycle life | 3,000 to 5,000 | More than 5,000 at 80% | 400 at 80%, 600 at 50%, 1,500 at 30% |
| Continuous discharge | 100 A; 200 A for 30 s | 100 A | Capacity drops at high current: 65% of rating over 1 hour |
| Maximum charge current | 50 A (0.5C recommended) | 100 A (50 A recommended) | Not stated on the datasheet |
| Absorption voltage | 14.2 to 14.6 V | 14.6 V in its parameter table | 14.2 to 14.6 V (normal cycle service) |
| Cold weather | 32 to 131 °F; BMS blocks charging below 32 °F | -22 to 131 °F; heater on below 41 °F | Capacity falls sharply at low temperature |
| Self-discharge | 2 to 3% a month | Not stated in the manual | Under 2% a month at 20 °C |
| Banks | Series to 48 V; parallel, no limit | Up to 4 in series, 8 in parallel | Victron advises about 3 or 4 parallel strings at most for lead acid |
Sources by column: Battle Born manual; Renogy manual; Victron AGM datasheet and Wiring Unlimited chapter 3.1345
Sources: Battle Born BB10012 manual, Renogy RBT12100LFP-H manual, Victron Gel and AGM datasheet, read 24 November 2026. Ratings are at different depths of discharge, shown under each bar; chart ours.134
Weight per usable energy, worked out from those figures: Battle Born's 100 Ah at 12 V and 100% depth of discharge is 1.2 kWh for 31 lb, about 26 lb per usable kWh. Victron's 110 Ah AGM used to 50%, the depth at which it is rated 600 cycles, gives 0.66 kWh for about 71 lb, about 107 lb per usable kWh.14 In a van, that weight comes off the payload.
Can lithium batteries charge below freezing?
Not standard LiFePO4. Battle Born's BMS blocks charging below 32 °F (0 °C) and allows discharge down to -4 °F (-20 °C). Heated models warm the cells first: Renogy's RBT12100LFP-H heats below 41 °F (5 °C) and charges down to -22 °F.13
Sources: Battle Born manual (BMS and specification pages), Renogy RBT12100LFP-H manual, Victron MPPT manual LiFePO4 defaults, read 24 November 2026; chart ours. Battle Born's manual lists discharge up to 135 °F in one table and 140 °F in another, and charging from 25 °F in one and 32 °F in another; we show the safer figure each time.139
Heaters need power to work. Battle Born's heated BB10012H turns its heater on at about 35 °F internal temperature and draws 28 W while enabled.1 Renogy says its heater needs a steady charge current above 10 A for each battery in a parallel bank, starts below 41 °F and stops above 50 °F.3 Chargers can help: Victron's MPPT lithium preset sets a low temperature cut off of 5 °C.9
Series, parallel, or one big battery?
Parallel adds amp-hours and current at the same voltage; series adds voltage. Battle Born allows its 12 V batteries in series up to 48 V and in parallel without limit; Renogy allows up to four in series and eight in parallel. Never mix battery types.13
Our drawing of the configurations in Battle Born's manual, with the diagonal connection Victron recommends for parallel banks.15
Parallel banks add current limits as well as capacity: two Battle Born BB10012s make a 12 V 200 Ah bank that can deliver 200 A continuously and 400 A for 30 seconds.1 Victron warns that a bank wired from one end works the end battery hardest; use busbars, equal length cables to each battery, or diagonal connection.5 Before wiring in series, Battle Born says to charge each battery to 14.2 to 14.6 V so all are at the same state of charge, and to charge a two-battery 24 V bank at 28.8 V with a 27.2 V float.1 Renogy asks for batteries to be balanced before connection, resting together in parallel for 12 to 24 hours.3
Where and how do you mount the battery?
Low, secured and close to the main fuse and busbars. Battle Born says vibration in vans is constant, so batteries must be secured so they cannot shift, slide or tip; its BB10012 may sit in any orientation, while Renogy allows any side but the terminal side.213
| 1 | Strap or bracket the battery so it cannot shift, slide or tip; route cables so they do not pull or twist the terminals.2 |
|---|---|
| 2 | Keep it dry: Battle Born says not where it may flood, and in a Type 3R enclosure outdoors.1 |
| 3 | Leave air around it: Renogy asks for enough air flow to prevent heat build-up and temperature differences between batteries.3 |
| 4 | Lug stack and torque from the manual: Battle Born bolt, washer, lug, terminal, washer, nut at 9 to 11 ft-lb; Renogy 6 to 8 N·m with no washer between lug and terminal.13 |
| 5 | Main fuse at the positive terminal, with an interrupt rating that covers the bank's short circuit current.6 |
| 6 | Do not mount a solar controller or inverter directly above the battery; Victron's manuals for both say never.78 |
We could not find a crash load figure for battery mounts in any maker document we opened, so we give none: use the battery maker's tray or bracket, or a bracket rated by its maker for the battery's weight.
What does a BMS do?
It watches every cell and disconnects the battery when something goes outside its limits: high or low voltage, high or low temperature, too much current, or a short circuit. Battle Born's BMS also balances the cells at the top of each charge, above about 14.2 V.1
Battle Born's BMS allows 100 A continuous, 200 A for 30 seconds and half a second for larger loads, and resets 5 seconds after an over-current trip. After a short circuit it stays off until the cables are removed, and it will not charge above 131 °F (55 °C) or discharge at 140 °F (60 °C) and over.1 Renogy's BMS covers the same faults with its own trigger and recovery voltages.3
A BMS is not a fuse. Battle Born recommends fuses and circuit breakers to protect downstream components, and Victron requires at least one fuse that can interrupt a lithium bank's maximum short circuit current.16 Set every charger to the battery's own profile; Victron's MPPT LiFePO4 default is 14.2 V absorption for 2 hours with equalization and temperature compensation off.9 Charge settings are covered in the solar charge controller guide.
Battle Born lists its cells as UL Recognized to UL 1642, UN38.3 tested, and the pack ETL Listed to UL 2054 and UL 62133-2.1 Renogy lists UN38.3 among its certifications.3 We did not open the standards themselves.
Who makes van batteries?
Verified battery makers in our directory include Battle Born, Renogy, SOK, Epoch, LiTime, Lithionics and Rich Solar.
More are in our parts directory. Next steps in the cluster: inverter size, fuses, wire size and charge controllers. Every build topic is on the DIY hub. Lithium batteries store a lot of energy: if you are unsure about any step, have a qualified electrician check the battery side before you power it up.
Questions people ask
Is a 100Ah lithium battery enough for a camper van?
Only if your loads use under about 1,200 Wh a day and you recharge daily: 100 Ah at 12 V is 1,200 Wh, and Battle Born rates its 100 Ah battery for 100% usable depth of discharge. Add up your own loads first, then add days without charging.
How long will a lithium battery last in a van?
In cycles, Battle Born states 3,000 to 5,000 for its BB10012 and Renogy more than 5,000 at 80% depth of discharge for its RBT12100LFP-H. Victron's AGM deep cycle range is rated 400 cycles at 80% and 600 at 50%. Years depend on how many cycles you use.
Can I replace AGM batteries with lithium without changing anything?
Not always. Every charger must be set for lithium: Battle Born asks for 14.2 to 14.6 V absorption, temperature compensation off and equalization off or 14.4 V. Lithium can also draw high current from an alternator, so most vans add a DC-DC charger.
Can lithium batteries go inside the living area of a van?
Battle Born says its batteries should be installed per national and local codes, not where they may flood, and in a Type 3R enclosure outdoors. Secure them and fuse them at the terminal. Check your battery's manual for its own rules.
What happens if a lithium battery is charged below freezing?
A good BMS refuses the charge. Battle Born's BMS blocks charging below 32 °F (0 °C) but allows discharge to -4 °F. Heated models warm the cells first: Renogy's heater runs below 41 °F (5 °C) when the charge current is over 10 A per battery.
Is one 200Ah battery better than two 100Ah batteries?
Either works if the bank is wired and fused right. Two of Battle Born's 100 Ah batteries in parallel give 200 Ah and 200 A continuous, double the current limit of one. Parallel banks must be wired so each battery sees the same cable path, Victron says.
What should I do if a lithium battery catches fire?
Get out first. Battle Born's emergency steps are to disconnect the battery from the system, wear a respirator, eye protection and rubber gloves where appropriate, and use an ABC type dry chemical fire extinguisher. Call emergency services for any fire in a vehicle.
How do I store a van's lithium battery over winter?
Battle Born says charge to 100%, then disconnect: remove the negative cable from one battery. Its storage range is -10 to 140 °F, and it warns that sub-zero storage below about -15 °F can crack the case and cost capacity.
Sources
Battery specs are from Battle Born's BB10012 manual, Renogy's RBT12100LFP-H manual and Victron's AGM datasheet; wiring rules from Victron's Wiring Unlimited. Amp-hour and weight figures in the charts are arithmetic on those numbers. SOK, Epoch, LiTime and Lithionics documents were not opened on their own sites, so their batteries are linked, not quoted. UL 1973 and UN 38.3 texts were not opened; we report only which listings a maker states. All read 24 November 2026.
- Battle Born Batteries, BB10012 and BB10012H 100Ah 12V LiFePO4 battery manual (document PMI_BB10012, revision 038, 12 August 2026). Read 24 November 2026
- Battle Born Batteries, How to Properly Mount and Secure Lithium Batteries (11 May 2026). Read 24 November 2026
- Renogy, Core Series 12.8V 100Ah Mini LiFePO4 battery with self-heating (RBT12100LFP-H) user manual, version A0, 25 November 2024. Read 24 November 2026. Renogy's own document, hosted on its EU site
- Victron Energy, Gel and AGM batteries datasheet (12 V Deep Cycle AGM range). Read 24 November 2026
- Victron Energy, Wiring Unlimited, chapter 3: Battery bank wiring. Read 24 November 2026
- Victron Energy, Wiring Unlimited, chapter 4: DC wiring (fuses, interrupt rating for lithium). Read 24 November 2026
- Victron Energy, SmartSolar MPPT 100/30 and 100/50 manual, Installation (mounting). Read 24 November 2026
- Victron Energy, Inverter VE.Direct 120V manual, Installation (location). Read 24 November 2026
- Victron Energy, SmartSolar MPPT 100/30 and 100/50 manual, Operation (LiFePO4 default settings). Read 24 November 2026
- Victron Energy, Inverter VE.Direct 120V manual, Technical specifications (zero-load power). Read 24 November 2026