Vanlife

Guides / Solar charge controller size: MPPT or PWM for a camper van

Solar charge controller size: MPPT or PWM for a camper van

The short answer

Pick an MPPT controller whose nominal PV power at your battery voltage covers the array and whose maximum PV voltage stays above the panels' open circuit voltage on the coldest morning. On a 12 V van, Victron's MPPT 100/30 covers 440 W and 100 V; for more panel watts, its 100/50 covers 700 W.

Last updated 24 November 2026

Key takeaways

  • Use MPPT for most vans: in Victron's test, PWM harvested 19% less from a 100 W panel at 25 °C, and MPPT lets you wire panels in series.
  • Size by watts and by volts: the controller's nominal PV power at your battery voltage must cover the array, and the cold open circuit voltage must stay under its maximum.
  • Victron's MPPT 100/30 handles 440 W on a 12 V battery and 100 V of panel voltage; two 36.5 V Renogy panels in series reach about 81 V at -4 °F.
  • Set the controller to the battery's profile: Victron's LiFePO4 default is 14.2 V for 2 hours; Battle Born allows 14.2 to 14.6 V.
  • Mount it within 3 m of the battery, never above it, with the manual's fuse on the battery side and a fuse and disconnect on the panel side.

Panel output and roof fit are in how much solar a van needs; this guide is about the box between the panels and the battery.

MPPT or PWM?

MPPT for most vans. A PWM controller pulls the panel to battery voltage; an MPPT converts at the panel's best point. Victron found 19% less from PWM at 25 °C, about the same at 75 °C, and calls PWM a low cost choice only for small systems.1

Same panel, two controllersPower harvested from a 100 W panel charging a 13 V battery
Cell at 25 °C, MPPT
100 W
Cell at 25 °C, PWM
81 W
Cell at 75 °C, MPPT
77.5 W
Cell at 75 °C, PWM
77 W

Source: Victron Energy white paper, Which solar charge controller: PWM or MPPT?, sections 4 and 5, read 24 November 2026; chart ours.1

The white paper's other findings matter on a van roof. MPPT has a clear advantage in partial shade, and at low irradiance an MPPT connected to a higher voltage array performs far better than PWM.1 Panels laid flat on a roof can run hot: Victron notes cells with an insulated back can exceed 100 °C, where a PWM controller may not fully charge a battery at all, and that an MPPT does best when the array voltage is well above the battery, for example 72 cells or more for a 12 V battery.1 MPPT also allows series wiring, which halves the current for the same power and lets you use thinner cable.1

How do you size a charge controller?

Two checks. Watts: the controller's nominal PV power at your battery voltage covers the array. Volts: the string's open circuit voltage at your coldest temperature stays under the maximum, and the panel voltage is at least 5 V above the battery.32

Controller sizing worksheet (copy it)
StepWhat to doExample: two Renogy 200 W panels in series, 12 V battery
1. Array wattsAdd the panels' rated watts.400 W7
2. Watts checkController's nominal PV power at your battery voltage must be at least the array watts.MPPT 100/30: 440 W at 12 V3
3. Charge currentArray watts / battery volts, roughly; the controller caps it at its rating.400 W / 13 V is about 31 A, under 30 A1
4. Coldest VocPanels in series x Voc x (1 + coefficient x (25 - coldest °C)).2 x 36.5 V x (1 + 0.0025 x 45) = 81.2 V at -20 °C7
5. Voltage checkColdest Voc must stay under the maximum PV voltage, with margin.81.2 V under 100 V: passes2
6. Start voltagePanel voltage must exceed battery voltage + 5 V to start.2 x 31.3 V Vmp = 62.6 V: passes73
7. Current checkArray short circuit current under the controller's maximum.6.86 A under 35 A73
8. FusesBattery fuse from the manual; fuse and disconnect between array and controller.35 to 40 A battery fuse210

Victron's manual says to take both the panel's open circuit voltage and its temperature coefficient into account, because below 25 °C the Voc is higher.2 Renogy publishes -0.25% per °C for its ShadowFlux 200 W panel.7 Use your own panel's datasheet figure and the coldest temperature you expect, and leave margin; the chart shows why a third panel in series does not fit a 100 V controller.

Cold weather voltageOpen circuit voltage of Renogy 200 W panels in series, at 77 °F and at -4 °F
0 V50100150170 V
1 panel in series36.5 V warm, 40.6 V cold
2 panels in series73.0 V warm, 81.2 V cold
3 panels in series109.5 V warm, 121.8 V cold
4 panels in series146.0 V warm, 162.4 V cold
100 V limit (MPPT 100/30, 100/50); 150/35 and 150/45 allow 150 V

Our arithmetic on Renogy's RSP200DC-ASR datasheet (Voc 36.5 V, -0.25%/°C) and Victron's 100 V and 150 V limits, read 24 November 2026; chart ours.725

Three in series reach 121.8 V at -20 °C: over a 100 V controller, inside a 150 V one. Four reach 162.4 V, over both, even though they read 146.0 V at 25 °C. Panels in parallel keep the voltage of one string and add current instead.

Controller sizing table: Victron SmartSolar limits and the smallest that fits
ControllerCharge currentNominal PV power, 12 VNominal PV power, 24 VMax PV voltageBattery fuse
MPPT 100/3030 A440 W880 W100 V35 to 40 A32
MPPT 150/3535 A500 W1000 W150 V40 to 45 A65
MPPT 150/4545 A650 W1300 W150 V50 to 63 A65
MPPT 100/5050 A700 W1400 W100 V55 to 70 A32
Smallest of these four controllers for each array (watts check only)
Array12 V battery24 V battery
200 WMPPT 100/30 (440 W)MPPT 100/30 (880 W)
400 WMPPT 100/30 (440 W)MPPT 100/30 (880 W)
600 WMPPT 150/45 (650 W)MPPT 100/30 (880 W)
800 WNone of these four; use two controllers or a larger modelMPPT 100/30 (880 W)

Computed from Victron's nominal PV power figures. Then run the voltage check: a 150 V model may be needed for three or more panels in series even when a 100 V model passes on watts.36

How do you set lithium charge settings?

Use the battery maker's profile. Battle Born asks for 14.2 to 14.6 V absorption, 13.4 to 13.8 V float, and temperature compensation off. Victron's LiFePO4 default is 14.2 V absorption for a fixed 2 hours with equalization off.84

Lithium settings: battery maker vs controller default (12 V; double for 24 V)
SettingBattle Born BB10012Victron MPPT LiFePO4 default
Absorption voltage14.2 to 14.6 V14.2 V
Absorption time30 minutes per 100 Ah battery in the bank2 hours, fixed
Float13.4 to 13.8 V13.5 V in one section of the manual, 13.2 V in another
Equalization14.4 V or disabledDisabled
Temperature compensationOffOff
ColdBMS blocks charging below 32 °F (0 °C)Low temperature cut off at 5 °C
Restart charge (rebulk)13.3 VFloat minus 0.1 V

Sources: Battle Born manual, charging profile and specifications; Victron MPPT manual, sections 6.2 and 6.4.84

Victron says its lithium values are recommended defaults that can be changed if the battery maker advises otherwise, and it warns never to equalize gel, AGM or lithium batteries.4 Battle Born's 24 V example, two batteries in series, uses 28.8 V absorption and 27.2 V float.8

Where does the controller go and how is it fused?

Close to the battery and never above it: Victron says within 3 m, mounted vertically on a non-flammable surface with 10 cm clear above and below. Fuse the battery side per the manual, and put a fuse and a disconnect between array and controller.210

Our drawing of the mounting and fusing rules in Victron's SmartSolar 100/30 and 100/50 manual and Wiring Unlimited.210

The manual also says the PV input is not isolated from the battery circuit, so both sides are hazardous and must be guarded against contact, in an enclosure or Victron's WireBox. Ground the system at a single point near the battery, never ground the PV positive or negative, and do not use panels with optimizers.2 Use flexible multi-stranded copper for the screw terminals.2 Cable sizes come from the wire size calculator, and fuse ratings from the fuse size guide.

Who makes charge controllers?

Verified makers in our directory that sell solar charge controllers include Victron Energy, Renogy, Go Power and REDARC, whose BCDC chargers have a built-in MPPT.9

More are in our parts directory. The rest of the electrical series: the whole system, solar panels, DC-DC chargers, inverters and lithium batteries. Every build topic is on the DIY hub.

Questions people ask

What size charge controller do I need for 400 watts of solar?

On a 12 V battery, one rated for at least 400 W of panels at 12 V. Victron rates its SmartSolar MPPT 100/30 for 440 W at 12 V, so it fits, as long as the array's cold open circuit voltage stays under 100 V.

Can I connect solar panels directly to a battery?

No. Victron's wiring book says solar panels are not allowed to be connected directly to a battery; a solar charger goes between them to turn the higher panel voltage into a charging voltage, or the battery will be damaged.

Can I connect more panel watts than the controller is rated for?

Victron says its controllers limit input power if more PV power is connected than the nominal rating. That is not true of voltage: the array's open circuit voltage must never exceed the maximum, 100 V on the 100/30 and 100/50, in any weather.

Is MPPT worth it over PWM in a van?

Usually. In Victron's white paper a PWM controller harvested 19% less than MPPT from a 100 W panel at 25 °C, about the same at 75 °C, and MPPT does better in partial shade and low light. Victron calls PWM a low cost option for small systems only.

Do I need a fuse between the solar panels and the controller?

Victron's wiring book says a fuse needs to be located between a PV array and the solar charger, subject to local rules, and its MPPT manual asks for a way to disconnect all current-carrying PV conductors. The battery side gets its own fuse from the manual's table.

Should a van solar controller be set to lithium?

Yes, to your battery's own profile. Victron's LiFePO4 default is 14.2 V absorption for 2 hours with equalization and temperature compensation off. Battle Born asks for 14.2 to 14.6 V absorption and 13.4 to 13.8 V float. Where they differ, follow the battery maker.

Can a DC-DC charger also be the solar controller?

Some can. REDARC's BCDC dual input chargers have a built-in MPPT solar regulator. Their solar input range is 9 to 32 V and takes unregulated panels only, so check panel voltage against it; series strings of larger panels need a separate controller.

How much power does the controller use itself?

Very little. Victron lists self-consumption of 30 mA at 12 V for the SmartSolar 100/30 and 100/50, which is under 1 Ah a day.

Sources

Controller limits, fuses and settings are from Victron's SmartSolar manuals and its PWM vs MPPT white paper; panel figures from Renogy's ShadowFlux datasheet; battery settings from Battle Born's manual. Cold voltage figures are our arithmetic with the panel's published temperature coefficient. Renogy's and Go Power's own controller manuals could not be opened, so their controllers are linked, not quoted. All read 24 November 2026.

  1. Victron Energy, white paper: Which solar charge controller: PWM or MPPT? (20 January 2020). Read 24 November 2026
  2. Victron Energy, SmartSolar MPPT 100/30 and 100/50 manual, Installation. Read 24 November 2026
  3. Victron Energy, SmartSolar MPPT 100/30 and 100/50 manual, Technical specifications. Read 24 November 2026
  4. Victron Energy, SmartSolar MPPT 100/30 and 100/50 manual, Operation (battery charging, LiFePO4 defaults). Read 24 November 2026
  5. Victron Energy, SmartSolar MPPT 150/35 and 150/45 manual, Installation. Read 24 November 2026
  6. Victron Energy, SmartSolar MPPT 150/35 and 150/45 manual, Technical specifications. Read 24 November 2026
  7. Renogy, ShadowFlux 120W/200W anti-shading solar panel datasheet (RSP200DC-ASR): Voc, Vmp, Isc and temperature coefficient of Voc. Read 24 November 2026. Renogy's own datasheet, hosted on its Spanish site
  8. Battle Born Batteries, BB10012 100Ah 12V LiFePO4 battery manual (revision 038, 12 August 2026), charging profile. Read 24 November 2026
  9. REDARC, BCDC Dual Input In-Vehicle Battery Charger instruction manual (built-in MPPT solar input). Read 24 November 2026
  10. Victron Energy, Wiring Unlimited, chapter 4: DC wiring, sections 4.6 (PV fuses) and 4.12 (Solar). Read 24 November 2026