Guides / Camper van water system: how to plumb a van
Camper van water system: how to plumb a van
The short answer
Plumb a camper van with a fresh water tank, a strainer, a 12V pump and PEX or hose lines to a faucet, with the sink draining to a grey tank. A typical pump moves 3.0 gallons a minute at about 4.5 amps. Fuse the pump, vent both tanks, leak test before the walls close, and drain or heat it before it freezes.21
Last updated 24 November 2026
Key takeaways
- A van water system is a fresh tank, a strainer, a 12V pump, pipe, a faucet and a grey tank; filters, accumulators and heaters are add-ons.
- A typical 12V diaphragm pump moves 3.0 gallons a minute and draws about 4 to 5 amps; SHURflo asks for its own fused circuit and at least 16 AWG wire.
- Water is heavy: NW Conversions lists its 20 gallon tank at 189 lb full, so place it low and between the axles.
- On national forest land, federal rules require waste water to be removed or left only where provided; carry grey water to a dump station.
- Leak test before the walls close, and drain or heat the system before it freezes.
Water in a van is a small loop: fill, store, pump, use, hold the waste, dump. Each step has one or two parts, and the diagram below shows them in order.
What parts make up a van water system?
A fresh tank with a fill and vent, a strainer, a 12V pump, flexible hose at the pump, pipe and fittings, a faucet, and a grey tank with a drain. Optional: an accumulator, a filter, a water heater with a check valve, a tank heater.12
Drawn by vanlife.co from the order of parts in SHURflo's manual and catalog. Blue is fresh water, brown is grey water, dashed lines are flexible hose. Order of parts only, not to scale.12
Copy this parts list into your build plan. Each line says what the maker or agency requires.
| # | Part | Job | What the source says |
|---|---|---|---|
| 1 | Fill port and inlet line | Gets water into the tank | Use parts made for drinking water; US law defines lead free plumbing as 0.25% lead or less on wetted surfaces.8 |
| 2 | Fresh water tank | Stores drinking water | Food-grade tank listed for potable water; the NW tanks here are not for pressure and must be vented.3 |
| 3 | Tank vent | Lets air in as water leaves | Required on an unpressurized tank.34 |
| 4 | Strainer | Stops debris before the pump | Required by SHURflo: at least a 50-mesh strainer on the pump inlet.1 |
| 5 | 12V diaphragm pump | Pressurizes the lines | For example 3.0 GPM, 55 psi shut-off, 4.5 A maximum (SHURflo 4009-101-A65).2 |
| 6 | Flexible hose at the pump | Keeps vibration out of the plumbing | At least 18 in of 1/2 in ID flexible high-pressure hose on both pump ports.1 |
| 7 | Accumulator (optional) | Smooths flow, cuts pump cycling | Charge it to the pump's restart pressure; SHURflo's by-pass pumps do not need one.21 |
| 8 | Filter | Drinking water quality | On a separate feed line, so it does not cause rapid pump cycling.1 |
| 9 | Check valve before a water heater | Keeps hot water out of the cold side | SHURflo recommends one on the water heater inlet.2 |
| 10 | Pipe and fittings | Carry water to the taps | PEX to ASTM F876 with push fittings: cut square, deburr, push to the depth mark.7 |
| 11 | Sink and faucet | Uses the water | Size the drain to reach a grey tank below it. |
| 12 | Grey water tank | Holds sink and shower water | A sloped tank drains fully; the 11 gal NW tank has a 2% grade and is listed for grey water.4 |
| 13 | Drain valves | Empties tanks and lines | Fit one at the lowest point; you need it to winterize.1 |
| 14 | Tank heater pad (cold climates) | Stops a tank freezing | 65 W, 4.8 A at 12V, on at 45°F and off at 68°F; fused and switched; plastic tanks only.5 |
Pressurized pump or manual pump?
A 12V pump gives running water at the turn of a tap; SHURflo's 4009 series moves 3.0 gallons a minute at 4.2 to 5.3 amps maximum. A hand or foot pump needs no wiring and wastes less water, but you pump every cup.2
| SHURflo 12V model | Flow | Shut-off pressure | Maximum amps |
|---|---|---|---|
| 4009-101-A322 | 3.0 GPM | 20 psi | 4.2 A |
| 4009-101-A542 | 3.0 GPM | 30 psi | 4.5 A |
| 4009-101-A872 | 3.0 GPM | 45 psi | 5.3 A |
| 4009-101-A652 | 3.0 GPM | 55 psi | 4.5 A |
SHURflo's installation rules for its 4008 Revolution, a by-pass pump, are a good checklist for any diaphragm pump: mount it on a solid surface within 6 feet of the tank, in at least 1 cubic foot of space for ventilation, with a 50-mesh strainer on the inlet and at least 1/2 inch inside diameter plumbing.1 It says the pump is for intermittent duty only, and to shut its power off when you leave the vehicle unattended.1 Trail Kitchens' galley modules, for comparison, come with a 50 psi, 3.5 GPM pump and 14 gallon flexible fresh and grey bladders.6
How do you wire and fuse the pump?
On its own fused circuit, with the fuse or breaker the pump's label specifies. SHURflo says 16 AWG minimum, 12 AWG recommended, a 10 amp minimum circuit and a 15 amp switch on the positive lead.1
| Round-trip wire length | Minimum wire size |
|---|---|
| 0 to 25 ft | 16 AWG1 |
| 25 to 50 ft | 14 AWG1 |
| 50 to 70 ft | 12 AWG1 |
| 70 to 110 ft | 10 AWG1 |
SHURflo's chart is for a 10% voltage drop on a 12V, 15 amp circuit, and the length is from the power source to the pump and back.1 It warns that wire that is too small lowers pump performance and can create a fire hazard. Water and 12V live side by side in a galley, so keep connections above where a leak would drip, and see our wire size chart and van electrical guide for fusing.
Do you need an accumulator?
Not with a by-pass pump: SHURflo says its 4008 Revolution needs none. With other pumps an accumulator cuts cycling and pulsation. SHURflo's smallest is a 24 ounce tank, pre-charged to 20 or 30 psi; charge it to the pump's restart pressure.12
The catalog says its accumulators go downstream of the pump, help prolong pump life and save battery power, and that its Revolution high flow pumps do not need one.2 If your pump cycles on and off with every faucet, the 4008 manual's troubleshooting list points first to restrictions in faucets and shower heads, and to a filter that should be on a separate feed line.1
PEX, push-fit or hose?
PEX tube with push fittings for the runs, and flexible high-pressure hose at the pump. SHURflo says not to connect the pump ports to rigid pipe, and SharkBite says to cut PEX square, deburr it and push it in to the depth mark.17
SharkBite's instructions limit its fittings to tube certified to PEX (ASTM F876, CSA B137.5), copper (ASTM B 88) or CPVC (ASTM D 2846), and say the joint is correct when the depth mark is within 0.005 inch of the release collar.7 SHURflo asks for at least 18 inches of flexible hose on both pump ports, anchored where it meets the hard plumbing, because rigid pipe carries pump vibration and noise and can crack components.1 For anything that carries drinking water, the EPA explains that US law defines lead free as a weighted average of 0.25% lead on wetted surfaces of pipes, fittings and fixtures.8 Road vibration loosens plumbing, so check every joint again after the first few hundred miles.2
Where do tanks go: inside or underneath?
Inside, a tank stays above freezing longer and is easy to reach, but takes floor and payload; underneath, it saves room but needs a heater pad in cold weather. Either way, keep it low and between the axles.345
Source: NW Conversions specifications as listed by AVC RIG. Full weight is the maker's figure.34
| Tank | Size | Where | Full weight |
|---|---|---|---|
| 20 gal wheel well tank (SP-L-20)3 | 45 x 12.5 x 16 in | Inside, beside the wheel well | 189 lb |
| 11 gal undercarriage tank (SP-UC-11)4 | 38 x 12.5 x 9.875 in | Under the van, by the sliding door step | 104 lb |
The 20 gallon tank fits the Sprinter 2500 wheel well directly; on a ProMaster the maker says it needs raising 3.5 inches to clear the larger wheel wells.3 The 11 gallon tank mounts between the Sprinter's frame and the sliding door step, is sloped at a 2% grade for grey water, and on gas-engine Sprinters needs a heat shield between it and the exhaust.4 Both tanks are listed as not designed for pressurized systems and must be vented.34 How tank weight shifts load between the axles is worked through in how to plan a van layout.
For a tank under the van, a 12V heater pad such as Facon's CW-T1218 draws 4.8 amps (65 watts) while heating, switches on at 45°F and off at 68°F from a built-in thermostat, must be fused and switched, and is for plastic tanks only. It must also have nothing resting on it, batteries especially.5
Where can you dump grey water?
At a dump station, or where a site provides for it. National forest rules require waste water to be removed or left only where provided. The BLM rule excludes wash water from its vehicle dumping ban but bans polluting water supplies.109
The Forest Service rule, 36 CFR 261.11, prohibits failing to dispose of sewage and waste water by removing it or depositing it where provided, and placing anything in or near water that may pollute it.10 The BLM rule, 43 CFR 8365.1-1, bans draining sewage or dumping waste other than wash water from any vehicle except where provided, and separately bans polluting water supplies.9 We did not open any state's grey water rules in this run, so check the state and campground you are in. The EPA warns that some holding tank chemicals harm septic systems, and lists ethylene glycol antifreeze among the chemicals to beware of.11 Toilets and black water are covered in our van toilet guide.
How do you winterize it?
Drain everything, run the pump to purge the lines, disconnect the pump ports, leave faucets open and pour potable antifreeze into drains and traps. SHURflo says freeze damage voids its warranty. Or keep the van and its tanks heated.15
Source: SHURflo 4008 manual, winterizing section. Check your water heater's and vehicle's own instructions too.1
To sanitize the system afterwards, SHURflo gives 2 ounces of household bleach per 15 gallons of tank, run through every faucet until you smell chlorine, left for 4 hours (or double strength for 1 hour), then drained and flushed once or twice.1 It calls a lack of sanitizing the number one reason pumps fail early.1
How do you test for leaks before closing the walls?
Fill the tank, run the pump up to its shut-off pressure, close every faucet and watch: a pump that restarts with no tap open is losing pressure somewhere. Check every joint, wait, check again, and only then close the walls.1
SHURflo's troubleshooting list says a pump that will not shut off, or cycles with no faucet open, points to leaks on the outlet side, leaky valves or air trapped in the water heater.1 Leave access panels at the pump, strainer, filter and every tank fitting; you will need them for cleaning and winterizing. Plan where the galley, tanks and pump sit with how to build a van kitchen.
Who makes van water tanks and pumps?
5 verified makers and sellers in our directory make or sell van water tanks, pumps and plumbing. Each links to its listing with its location.
- Northwest Conversions, Washington: Makes wheel well, undercarriage and spare tire water tanks for Sprinter, Transit and Promaster vans, for professional upfits or DIY projects.
- Go Code Overland, Bargersville, Indiana: Bargersville, Indiana maker of interior trim kits, water tanks, showers, water heaters and hardware for Sprinter, Transit and ProMaster van builds.
- Munster Simms Engineering Ltd., Bangor, Northern Ireland, United Kingdom: Makes Whale water pumps, plumbing, taps, sockets and heating systems for campervans, caravans and motorhomes, plus marine water systems.
- Vanlife Outfitters, Sarasota, Florida: Sarasota, Florida store for camper van electrical systems, batteries, solar, suspension, water tanks, swivels and other road-tested van parts.
- Camco, Greensboro, North Carolina: Greensboro, North Carolina maker of aftermarket parts and accessories for the RV and outdoor recreation market, since 1966.
More on the parts page and the kits page; every DIY guide is on the DIY hub. Related: van layout, the floor, insulation and the whole build order.
Questions people ask
What parts do you need for a camper van water system?
A fresh tank with a fill and a vent, a strainer, a 12V pump, pipe and fittings, a faucet and sink, and a grey water tank with a drain valve. A filter, an accumulator, a water heater with a check valve and a tank heater are optional extras.
What size water pump does a van need?
A small 12V diaphragm pump is the usual choice. SHURflo's 4009 series moves 3.0 gallons a minute and draws 4.2 to 5.3 amps at most on 12V, depending on its shut-off pressure, by the maker's catalog.
Do you need an accumulator tank?
Not with a by-pass pump such as SHURflo's 4008 Revolution, which its manual says needs no accumulator. With other pumps, an accumulator reduces cycling and pulsation; SHURflo says to charge it to the pump's restart pressure.
Should the water tank go inside or under the van?
Inside is warmer and easier to service but uses floor space; under the van saves space but needs heat in freezing weather. NW Conversions' 20 gallon tank sits beside the wheel well; its 11 gallon tank mounts under the sliding door step.
What pipe should you use in a van?
PEX tubing to ASTM F876 with push fittings is common because it bends and needs no glue or torch. SharkBite says to cut the tube square, deburr it and push it in until the depth mark meets the release collar.
Where can you dump grey water from a van?
At a dump station is always safe. On national forest land, federal rules require waste water to be removed or put where provided. The BLM rule excludes wash water from its vehicle dumping ban but still bans polluting water supplies.
How do you winterize a van water system?
Drain the tank, open every faucet and the lowest drain, run the pump to purge the lines, disconnect the pump ports and run it dry, leave the faucets open, and pour potable antifreeze into drains and traps, as SHURflo's manual sets out.
How do you sanitize a van water tank?
SHURflo's manual says 2 ounces of household bleach per 15 gallons of tank, run through every faucet until you smell chlorine, left for 4 hours (or double strength for 1 hour), then drained and flushed.
Sources
Pump, accumulator, tank, heater pad and fitting figures are the makers' published figures. The SHURflo manual is revision K of document 911-1008, hosted by an RV dealer; the pump catalog is SHURflo's EMEA edition, whose 12V figures we quote. NW Conversions tank figures are as listed on AVC RIG's store. Dumping rules are quoted from federal regulations. We did not open a maker page certifying a drinking water hose, so we name no hose certification. Read 24 November 2026.
- Pentair SHURflo, 4008 RV Revolution By-Pass Pump Installation and Operation Manual, 911-1008 Rev. K (PDF, as hosted by an RV dealer). Read 24 November 2026
- Pentair SHURflo, RV catalog (EMEA edition, PDF): 4009 pumps, accumulators and system notes. Read 24 November 2026
- NW Conversions 20 gallon wheel well water tank (SP-L-20), specifications as listed by AVC RIG. Read 24 November 2026
- NW Conversions 11 gallon Sprinter undercarriage fresh or grey water tank (SP-UC-11), specifications as listed by AVC RIG. Read 24 November 2026
- GoCode Overland, Facon CW-T1218 12V tank heater pad (product page and specifications). Read 24 November 2026
- Trail Kitchens, Galley with Fridge Slide (product page). Read 24 November 2026
- SharkBite (Reliance Worldwide), Installation Instructions, SharkBite Connection System (PDF, as hosted by The Home Depot). Read 24 November 2026
- US EPA, Use of Lead Free Pipes, Fittings, Fixtures, Solder and Flux for Drinking Water. Read 24 November 2026
- 43 CFR 8365.1-1, Sanitation (Bureau of Land Management), via Cornell Legal Information Institute. Read 24 November 2026
- 36 CFR 261.11, Sanitation (National Forest System), via Cornell Legal Information Institute. Read 24 November 2026
- US EPA Region 9, Alert for RV, Boat and Mobile Home Owners and Park Operators about Safe Wastewater Disposal, EPA 909-F-99-002 (PDF). Read 24 November 2026