Vanlife

Guides / Battery isolator vs DC-DC charger: which does a van need?

Battery isolator vs DC-DC charger: which does a van need?

The short answer

With a lithium house battery or a smart alternator, you need a DC-DC charger, not an isolator: the charger isolates the batteries and also delivers the right charge voltage and current. An isolator or voltage sensing relay is a cheaper fit only for a lead acid or AGM house battery on a conventional alternator. Fuse both battery ends either way.

Last updated 25 November 2026

Key takeaways

  • An isolator joins the starter and house batteries while the engine charges and separates them when it stops; it does not shape the charge.
  • With a lithium house battery, use a DC-DC charger: REDARC's isolator manual lists only lead acid types, and Victron says lithium can overload an alternator without controlled charging.
  • Voltage sensing relays switch on voltage: REDARC's SBI12 at 13.2 V on and 12.7 V off; Victron's Cyrix-ct from 13.0 to 13.8 V on, 11 to 12.8 V off.
  • Smart alternators run about 12.5 to 15 V and can fall to 12.6 V (Victron), which can keep a relay open and stays below lithium absorption of 14.2 to 14.6 V.
  • On REDARC's US store an SBI12 isolator was $140.25 and its BCDC DC-DC chargers $454.75 to $586.50; fuse both battery ends either way.

How to fit a DC-DC charger is in our DC to DC charger guide; this page decides whether you need one, or whether an isolator will do.

Isolator or DC-DC charger: how do you decide?

Two questions settle it: what chemistry is the house battery, and does the van have a smart alternator? Lithium or a smart alternator points to a DC-DC charger. Lead acid or AGM on a conventional alternator can use an isolator.110

Our flowchart, from REDARC's isolator manual (battery types), Victron's Cyrix Li-ion datasheet and Orion XS manual (lithium and smart alternators), and Battle Born's charge profile.17101112

What does a battery isolator do?

It lets one alternator charge two batteries without the house loads draining the starter battery. A relay type connects the batteries once the starter battery shows charge and disconnects when it falls; a diode or FET type never connects them, it only lets current flow outwards.186

REDARC describes its Smart Start SBI as a microprocessor controlled isolator that, once the start battery has some charge from the alternator, connects the auxiliary battery to the charge circuit, and disconnects it when the start battery voltage drops too low.1 Victron's Argo isolators allow simultaneous charging of two or more batteries from one alternator without connecting the batteries together.8 Neither regulates the voltage: what the alternator makes is what the house battery gets, less any drop across the device and the cable.

Five ways to charge from the alternator (copy it)
TypeExampleHow it switchesLoss or limitBattery types
Voltage sensing relayREDARC SBI12, Victron Cyrix-ctCloses on charging voltage, opens when it falls15Virtually no voltage loss (Victron); 100 A and 120 A continuous51REDARC: lead acid, calcium, gel, AGM, SLI, deep cycle1
Lithium combinerVictron Cyrix-Li-ctCloses at 13.4 V if the VE.Bus BMS allows; opens below 13.2 V or on a BMS alarm7Needs Victron's BMS signal7Lead acid starter with Victron LiFePO47
Diode isolatorVictron ArgodiodeNever connects the batteries9About 0.3 V drop at low current, 0.45 V at rated output9Not stated
FET isolatorVictron ArgofetNever connects the batteries8Under 0.02 V at low current, about 0.1 V at higher currents8Not stated
DC-DC chargerREDARC BCDC, Victron Orion XSIsolates when the vehicle is off; charges with its own profile310Output capped at its rating (25 to 50 A)3AGM, gel, lead acid, calcium, LiFePO4 (REDARC)3

How does a voltage sensing relay decide when to connect?

By the voltage it sees. REDARC's SBI12 connects at 13.2 V after 5 seconds and disconnects at 12.7 V after 10. Victron's Cyrix-ct connects between 13.0 and 13.8 V and disconnects between 11 and 12.8 V, waiting longer the closer the voltage is to the threshold.15

Switching windows, 12 V systemsWhen two relays connect and disconnect, against smart alternator and lithium charging voltages
11 V12131415 V
REDARC SBI12off at 12.7 V, on at 13.2 V
off
on
Victron Cyrix-ctdisconnect 11 to 12.8 V, connect 13.0 to 13.8 V
opens, 0 s to 3 min
closes, 10 min to 4 s
closed
Smart alternator (Victron)about 12.5 to 15 V; about 12.6 V when off
varies
Battle Born absorption14.2 to 14.6 V
DisconnectedConnecting, with delayConnectedLithium absorption

Sources: REDARC SBI manual specifications; Victron Cyrix-ct datasheet delay table; Victron Orion XS manual, section 4.1.2; Battle Born BB10012 manual. Chart ours.151112

Victron's Cyrix-ct looks at the voltage trend rather than a fixed delay: near 13.0 V it waits about 10 minutes before connecting, above 13.6 V about 4 seconds; on the way down it disconnects at once below 11 V and after about 3 minutes between 12.4 and 12.8 V.5 Both makers build in a start assist: Victron's holds the relay closed for 30 seconds from a push button, REDARC's runs while the button is held.51 REDARC's dual sensing SBI12D connects if either battery exceeds 13.2 V, so solar on the house battery can also top up the starter battery.1

Why do lithium batteries usually need a DC-DC charger instead?

Three reasons from the makers. REDARC specifies its isolator for lead acid types only; an isolator passes whatever voltage the alternator makes, often below lithium's 14.2 to 14.6 V absorption; and nothing limits the current a lithium battery pulls from the alternator.11210

REDARC's isolator manual says to use it only for charging standard automotive lead acid, calcium, gel, AGM, SLI or deep cycle batteries.1 Victron says Euro 5 and 6 smart alternators often supply charging voltage that is too low even with the engine running, and that controlled charging protects the alternator in lithium systems from overloading, because lithium's low impedance results in a high alternator current.10 Battle Born asks for 14.2 to 14.6 V absorption and recommends charging at 0.5C, 50 A per 100 Ah battery.12 A relay has no current setting of its own: Victron's Cyrix-ct is simply rated 120 A continuous.5

There is a lithium relay: Victron's Cyrix-Li-ct parallels a lead acid starter battery and a LiFePO4 battery only when Victron's VE.Bus BMS allows charging and it senses 13.4 V, and opens below 13.2 V or on a cell over voltage or over temperature signal.7 It is built for Victron's own batteries and BMS. REDARC also sells an SBI12-LLD for LiFePO4, but it is a load disconnect that protects the lithium battery from over-discharge by loads, not a charging isolator.4

Voltage lost on the wayVoltage drop across the device at rated or higher current, from Victron's datasheets
Argodiode diode isolatorabout 0.3 V at low current
0.45 V
Argofet FET isolatorunder 0.02 V at low current
0.1 V
Cable: 50 A, 10 mm² (AWG 7), 5 mVictron's own example
0.35 V

Sources: Victron Argodiode and Argofet datasheets. Victron says the Cyrix relays have virtually no voltage loss but gives no figure. Chart ours.985

Victron warns that inserting a diode isolator slightly reduces charge voltage, so batteries may not reach 100% and age prematurely, and that some alternators need voltage on their B+ output to start charging, which a diode or FET isolator blocks unless you wire its energize input.98 A DC-DC charger avoids both: it regulates its output whatever the input voltage.10

What does each cost?

From one maker on one day: REDARC's US store listed its SBI12 isolator at $140.25 on sale ($165.00 regular) and its BCDC DC-DC chargers at $454.75 to $586.50 on sale. A DC-DC charger costs about three to four times as much.23

REDARC US store, 25 November 2026Sale price of REDARC isolators and DC-DC chargers
REDARC SBI12 isolator, 100 Aregular $165.00
$140.25
REDARC SBI12D dual sensing isolator, 100 Aregular $195.00
$165.75
REDARC BCDC1225D DC-DC charger, 25 Aregular $535.00
$454.75
REDARC BCDC1240D DC-DC charger, 40 Aregular $620.00
$527.00
REDARC BCDC1250D DC-DC charger, 50 Aregular $690.00
$586.50

Prices as shown on REDARC's US site; they change, and fuses and cable are extra. Chart ours.23

Fuses and cable cost about the same either way, since both run a positive cable from the starter battery to the house battery. REDARC asks for 8 mm² (8 B&S) cable and a 60 A fuse up to 3 m on the SBI12 without the start override, and 19 mm² with a 100 A fuse if you fit the override.1 The DC-DC charger tables, with cable by length, are in the DC-DC charger guide.

How do you wire and fuse an isolator?

Mount it near the starter battery, ground it to clean chassis metal, and put a fuse or breaker at the battery end of both positive cables. Victron limits the fuse on its 120 A Cyrix to 120 A, sized to the cable.16

Our diagram of REDARC's and Victron's installation steps.16

Isolator install checklist (copy it)
1Confirm both batteries are lead acid types the isolator is specified for; if the house battery is lithium, stop and fit a DC-DC charger.110
2Disconnect the negative of both batteries before working.6
3Mount near the start battery, out of direct engine heat (REDARC); Victron says closest to the smallest battery, usually the starter.16
4Ground the isolator to chassis with paint removed; REDARC says a good ground ensures correct switching voltage.1
5Fuse or breaker at the battery end of both positive cables, sized from the maker's cable chart.16
6Test: charge the start battery and listen for the click at the ON voltage; switch off and check it releases at the OFF voltage, which may take days on a full battery.1

Victron's general rule is that each consumer connected to a battery has its own fuse in the positive cable.13 Fuse ratings and holders are in the fuse size guide, cable in the wire size calculator, and the whole system in how to wire a camper van. If the van's alternator or battery connection points are unfamiliar, have an auto electrician make the starter battery connection.

Who sells isolators and DC-DC chargers?

These 6 verified makers in our directory sell isolators, DC-DC chargers or both; each links to its listing.

More in parts makers and kit makers. To size the house battery the charger feeds, see the lithium battery guide and the power budget guide; every step is on the DIY hub.

More electrical guides: solar sizing, charge controllers, series vs parallel panels, flexible vs rigid panels, inverters, inverter chargers, shore power, battery monitors and the wiring diagram. The whole build order is in the DIY van build guide.

Questions people ask

Do I need a battery isolator in a camper van?

You need something that charges the house battery from the alternator without letting the house loads drain the starter battery. With lead acid or AGM house batteries a voltage sensing isolator can do that. With lithium, use a DC-DC charger, which isolates the batteries as well as charging them.

Can I use a battery isolator with a lithium battery?

Not a standard one. REDARC's Smart Start manual says to use its isolator only for lead acid, calcium, gel, AGM, SLI or deep cycle batteries. Victron's lithium combiner, the Cyrix-Li-ct, works only with a signal from Victron's VE.Bus BMS. Victron says lithium's low impedance can overload the alternator without controlled charging.

What is the difference between a battery isolator and a DC-DC charger?

An isolator is a switch or diode: it joins the batteries when the starter battery shows charge and parts them when it falls, passing the alternator's voltage through. A DC-DC charger converts the alternator's power into a full charge profile for the house battery and limits the current, whatever the input voltage.

What is a voltage sensitive relay?

A relay that closes when it senses charging voltage and opens when the voltage falls. REDARC's SBI12 connects at 13.2 V and disconnects at 12.7 V; Victron's Cyrix-ct connects between 13.0 and 13.8 V and disconnects between 11 and 12.8 V, with delays set by the voltage trend.

Do battery isolators work with smart alternators?

Often badly. Victron says smart alternators vary between about 12.5 and 15 V and can switch off, dropping the starter battery to about 12.6 V. That can sit below an isolator's connect voltage, so it never closes, and it is below a lithium battery's absorption voltage when it does.

How much does a battery isolator cost compared with a DC-DC charger?

From one maker on one day, REDARC's US store listed its SBI12 isolator at $140.25 on sale and its 25 A to 50 A BCDC DC-DC chargers at $454.75 to $586.50 on sale. Add fuses and cable to either.

Where do the fuses go on a battery isolator?

At the battery end of both positive cables. REDARC says to install the fuse or breaker at the battery end of both positive cables, and Victron's Cyrix manual says to fuse to suit the cable, not above 120 A on the 120 A unit. Each battery can feed a short in the cable between them.

Is a diode isolator worse than a relay?

It drops voltage. Victron's Argodiode isolators lose about 0.3 V at low current and 0.45 V at rated output, and Victron warns the result can be batteries that never reach 100% and age early. Its FET isolators drop under 0.02 V to about 0.1 V.

Sources

Switching voltages, delays, voltage drops, current ratings and fuse rules are from REDARC's and Victron's manuals and datasheets; the lithium charging profile from Battle Born's manual; smart alternator behaviour from Victron's Orion XS manual; prices from REDARC's US store on 25 November 2026. Blue Sea Systems' and Sterling Power's documents could not be opened (403 and throttled), so their products are not quoted. Read 25 November 2026.

  1. REDARC, Smart Start Battery Isolator SBI12, SBI24, SBI212, SBI224 and dual sensing models, instruction manual (DOC424, version 12). Read 25 November 2026. REDARC's own manual, as filed with the SEMA Data catalog
  2. REDARC US, Dual Battery Isolators (category page with SBI prices). Read 25 November 2026. Prices shown that day
  3. REDARC US, BCDC in-vehicle DC battery chargers (range page with prices; built-in isolation). Read 25 November 2026. Prices shown that day
  4. REDARC US, Smart Start Load Disconnect Isolator SBI12-LLD (product page). Read 25 November 2026
  5. Victron Energy, Cyrix-ct 12/24 V 120 A and 230 A intelligent battery combiner datasheet. Read 25 November 2026
  6. Victron Energy, Cyrix-ct 12/24V and 24/48V 120A manual (revision 05, 8 June 2022). Read 25 November 2026
  7. Victron Energy, Cyrix Li-ion 120 A series datasheet (Cyrix-Li-ct, Cyrix-Li-Charge, Cyrix-Li-load). Read 25 November 2026
  8. Victron Energy, Argofet battery isolators with alternator energize input, datasheet. Read 25 November 2026
  9. Victron Energy, Argodiode battery isolators, datasheet. Read 25 November 2026
  10. Victron Energy, Orion XS 12/12-50A DC-DC battery charger manual, General (smart alternators, lithium alternator overload). Read 25 November 2026
  11. Victron Energy, Orion XS 12/12-50A manual, Operation (Euro 6 alternators, 12.5 to 15 V). Read 25 November 2026
  12. Battle Born Batteries, BB10012 100Ah 12V LiFePO4 battery manual (revision 038, 12 August 2026): charging profile. Read 25 November 2026
  13. Victron Energy, Wiring Unlimited, chapter 4: DC wiring (a fuse for every positive cable). Read 25 November 2026