Guides / Camper van wiring diagram: a 12 V lithium system, labelled
Camper van wiring diagram: a 12 V lithium system, labelled
The short answer
A camper van wiring diagram shows the house battery, its main fuse and switch, a positive and a negative busbar with a shunt, each charger (solar, alternator, shore) fused into the busbar, a fuse block for 12 V loads and an inverter on its own fuse, with the wire size and fuse rating on every line. Below is a typical 12 V lithium system, labelled from the parts' manuals, and its 24 V variant.
Last updated 25 November 2026
Key takeaways
- A van wiring diagram is a map of fuses and wires: every line shows the wire size, the fuse at its source end and the manual that sets them.
- In a 12 V lithium build the inverter line carries the most current: about 196 A for a 2,000 W inverter, on a 250 A Class T fuse and 2/0 AWG at 6 ft in Samlex's table.
- Check every manual's cable against its fuse: Samlex's 2 AWG at 3 ft is rated 210 A by Table 5, below its 250 A fuse, so under Victron's rule it goes up a size.
- The shunt sits alone on the battery negative; every other negative goes to the negative busbar, or the battery monitor misses it.
- A 24 V layout is the same drawing with half the current: Samlex's 2,000 W inverter fuse drops from 250 A to 125 A, and 12 V loads need a converter.
This is the drawing behind how to wire a camper van. The numbers on it come from the cluster: wire size, fuse size and inverter size.
What does a camper van wiring diagram look like?
Charge sources on one side, the house battery on the other, and busbars between them. Each charger feeds the positive busbar through a fuse; the battery joins it through a main fuse and switch; loads and the inverter leave it through their own fuses; negatives return through a shunt.210
Our diagram. Fuses and limits from the Victron, Samlex and Battle Born manuals; 1/0 and 8 AWG are our sizing for the example lengths in the table below. On a phone, scroll the drawing sideways.5694102
The parts are examples so that every number can be traced: two Battle Born BB10012 batteries in parallel make a 12 V, 200 Ah bank able to deliver 200 A continuously, since each is rated 100 A continuous; Battle Born says its batteries can be paralleled without limit.4 A Victron SmartSolar MPPT 100/30 needs a 35 to 40 A battery fuse and an array open circuit voltage under 100 V.5 A Victron Orion XS 12/12-50A takes a 60 to 70 A fuse and 6 AWG cable under 5 m.6 A Samlex PST-2000-12 inverter needs a 250 A Class T or equivalent fuse within 7 in of the battery positive.9 Your parts will differ; take every number from your own manuals.
How do you read a van wiring diagram?
Follow each line from its power source. The fuse sits at the source end, the label beside the line gives the wire size, and the box gives the part. Red is positive, black negative, dashed is 120 V or optional. Every positive line needs a fuse before it.2
Three rules from Victron's Wiring Unlimited explain most of the drawing. Every consumer connected to a battery gets its own fuse in the positive cable. A DC system always has a main fuse, and pulling it is enough to isolate the battery. And on lithium, at least one fuse must be able to interrupt the bank's full short circuit current, which is why the main fuse is a Class T.2 If you add a battery switch, Victron recommends switching only the positive, with a switch rated for DC at full load current.2
Where does each fuse go, and what wire does each line need?
Each fuse goes at the power source end of its cable: at the battery, the busbar, and the starter battery for a DC-DC charger. Its rating comes from the part's manual and must never exceed the cable's rating; the cable comes from the manual or a voltage drop calculation.296
This is the line schedule for the 12 V diagram, the part of a wiring diagram worth copying. Where a manual gives the cable we show it; otherwise the wire is our pick, the smallest gauge that keeps the drop at 3% over the example length and is rated at least as high as both the current and the fuse.14132
| Line | Part and current | Fuse | Example one-way length | Wire |
|---|---|---|---|---|
| Battery to busbar (main) | Two BB10012 in parallel, 200 A continuous | Class T, no higher than the cable (our rule check)429 | 3 ft | 1/0 AWG (our pick, rated 285 A) |
| Inverter | Samlex PST-2000-12, about 196 A at full output | 250 A Class T within 7 in9 | 6 ft | 2/0 AWG at 6 ft (2% drop column) (manual) |
| Solar controller to busbar | Victron SmartSolar MPPT 100/30, 30 A out | 35 to 40 A5 | 6 ft | 8 AWG (our pick, rated 80 A) |
| DC-DC charger to busbar | Victron Orion XS 12/12-50A, 50 A out | 60 to 70 A6 | 6 ft | 6 AWG under 5 m, 4 AWG from 5 to 10 m (manual) |
| Fuse block feed | Example: 30 A of 12 V loads at once | No higher than the feed cable2 | 4 ft | 10 AWG (our pick, rated 60 A) |
| One load circuit | Example: a 20 A load 10 ft from the block | Device manual, else no higher than the cable2 | 10 ft | 8 AWG (our pick, rated 80 A) |
Our picks: 3% drop at 12 V, 105 °C copper, Ancor's formula and Table 5 ampacity, never below the fuse. The battery line is checked against the 250 A inverter fuse it carries, so its Class T main fuse must not exceed the cable rating shown. Lengths are examples; use yours.14132
One check most diagrams skip: hold each manual's cable against its fuse. Samlex lists 2 AWG at 3 ft (2% drop) for the PST-2000-12 with a 250 A fuse.9 Table 5 rates 2 AWG at 210 A even with 105 °C insulation, below the fuse,13 and Victron's rule is that a fuse may not be rated above its cable.2 So on our diagram the inverter runs on the 6 ft row, 2/0 AWG, rated 330 A. Samlex itself says final cable sizing should be decided by a qualified electrician.9
Source: Samlex PST manual Table 8.3, Victron Orion XS and MPPT 100/30 manuals, read 25 November 2026; the two grey rows are our examples. Chart ours.965
Where does the shunt go in the diagram?
Between the battery negative and the negative busbar, alone. Victron's SmartShunt manual puts only the battery negative on the BATTERY MINUS side and every load, inverter and charger negative on the other side; anything on the battery side is left out of the state of charge.10
The shunt has to be rated for the biggest current the system will see. Victron's example: a 3,000 VA inverter with a 6,000 W peak draws 500 A at 12 V, so the shunt must handle that.2 The details, settings and the cheaper alternatives are in do you need a battery monitor.
How does a 24 V van wiring diagram differ?
Same layout, half the current. Two 12 V batteries go in series, the inverter takes a 24 V model with a smaller fuse and cable, the alternator charges through a 12 to 24 V DC-DC charger, and 12 V loads hang off a 24 to 12 V converter.498
Our diagram. Battery from Battle Born, inverter from Samlex, chargers and converter from Victron's Orion-Tr and MPPT manuals, shunt setting from the SmartShunt manual.4978511
Battle Born says two BB10012s in series make a 24 V 100 Ah bank, charged at 28.8 V with a 27.2 V float, and that its batteries can go in series up to 48 V.4 Samlex's PST-2000-24 takes a 125 A fuse and 4 AWG at 6 ft (2% drop) or 6 AWG (3%).9 Victron's non-isolated Orion-Tr table puts a 60 A fuse on a 12 V side and a 30 A fuse on a 24 V side; the 12/24-15 delivers 15 A at 24 V and the 24/12-30 delivers 30 A at 12 V.78 On 24 V, Victron's MPPT manual asks for at least 72 cells in series, two 12 V panels or one 24 V panel.5 And the battery monitor's charged voltage for 24 V lithium is 27.8 V.11
Formula (watts / volts x 85% at 12 V, 88% at 24 V) and fuses from Samlex's PST manual, read 25 November 2026; arithmetic and chart ours.9
| Line | Part and current | Fuse | Example one-way length | Wire |
|---|---|---|---|---|
| Battery to busbar (main) | Two BB10012 in series, 24 V 100 Ah, 100 A continuous | Class T, no higher than the cable (our rule check)429 | 3 ft | 4 AWG (our pick, rated 160 A) |
| Inverter | Samlex PST-2000-24, about 95 A at full output | 125 A Class T within 7 in9 | 6 ft | 4 AWG at 6 ft (2% drop column) (manual) |
| Solar controller to busbar | Victron SmartSolar MPPT 100/30 on 24 V | 35 to 40 A5 | 6 ft | 12 AWG (our pick, rated 45 A) |
| DC-DC charger, 24 V side | Victron Orion-Tr Smart 12/24-15, 15 A out | 30 A (24 V row)78 | 6 ft | 14 AWG (our pick, rated 35 A) |
| DC-DC charger, starter side | Same charger, 12 V input, about 30 A (our estimate) | 60 A (12 V row)7 | 10 ft | 16 mm² at 5 m and 10 m (12 V row) (manual) |
| 24 V to 12 V converter, 24 V side | Victron Orion-Tr Smart 24/12-30 for 12 V loads | 30 A (24 V row)78 | 4 ft | 14 AWG (our pick, rated 35 A) |
The 12/24-15's 12 V input current is our estimate from power balance (15 A x 24 V / 12 V, before losses), so the manual's 60 A fuse and cable govern that line. Our picks use the same method as the 12 V table.71413
How do you add shore power and alternator charging to the diagram?
Alternator charging is a DC-DC charger fused at both ends, drawn like any other charger. Shore power enters through an inlet and an RCD (GFCI) to a charger or inverter charger; that 120 V part is drawn by, and wired by, a licensed electrician.612
On the DC side the shore charger is one more fused line into the positive busbar. On the AC side Victron's shore power guide lists an external waterproof inlet, a shore cable, a consumer unit (breaker box) with an RCD and breakers, and, with an inverter charger, a second consumer unit on its output.12 We do not draw AC wiring beyond that: grounding and the neutral to ground link change between shore and inverter mode, and Victron's book shows a double link causes trouble.3 Read adding shore power to a van and inverter chargers first, then hire the electrician.
What should your own diagram include before you buy parts?
Every part with its model, every line with its one-way length, wire size and fuse rating, the manual page each number came from, the shunt position, the system voltage, and a dashed line around everything at 120 V. Check it against the manuals before ordering.
| Check | Why |
|---|---|
| A fuse on every positive line, at the source end | Each consumer fused individually after a main fuse.2 |
| Main fuse with enough interrupt rating | Mandatory on lithium: at least one fuse must break the bank's short circuit current.2 |
| Each fuse at or below its cable's rating | Victron's rule; check even the manual's own cable.213 |
| DC-DC charger fused at both batteries | Both ends can feed a short; the Orion XS takes 60 to 70 A.6 |
| Shunt alone on the battery negative | Otherwise loads or chargers are left out of the state of charge.10 |
| Shunt rated for the inverter's peak | Victron's 3,000 VA, 6,000 W peak example draws 500 A at 12 V.2 |
| Battery current covers the inverter | 196 A against 100 A continuous per BB10012: two in parallel at least.49 |
| 120 V marked for a licensed electrician | Inlet, RCD (GFCI), breakers, outlets, grounding.123 |
Victron's book also says electrical work should be done by a qualified electrician or technician and that rules vary by place; a diagram is the cheapest moment to have one look.1 When the drawing is done, follow the wiring order and test before the walls close.
Who makes the parts on the diagram?
These 7 verified businesses in our directory make or sell the batteries, chargers, inverters, monitors or complete van electrical kits on diagrams like these; each links to its listing.
- Victron Energy B.V., Almere, Netherlands: Maker of off-grid energy equipment such as inverters, chargers, batteries, battery monitors and solar charge controllers, used in vans, boats and buildings.
- Battle Born, Reno, Nevada: Sells LiFePO4 lithium batteries, solar gear, inverters and power components for RV, trucking, marine and off-grid use from Reno, Nevada.
- Samlex America, Burnaby, British Columbia, Canada: Maker of power inverters, inverter chargers, battery chargers, DC-DC converters and Samlex Solar products for RV, marine and off-road use.
- Renogy, Ontario, California: Ontario, California maker of solar panels, lithium batteries, inverters and off-grid power kits for RVs, vans, marine and cabins.
- REDARC Electronics, Grapevine, Texas: Makes automotive electronics including dual battery chargers, complete van and overlanding power kits, inverters, solar panels and towing brake controllers.
- Explorist.life, Redmond, Oregon: Husband-and-wife business selling camper electrical systems, components and wiring kits for DIYers, with professional installation in Redmond, Oregon.
- Vanlife Outfitters, Sarasota, Florida: Sarasota, Florida store for camper van electrical systems, batteries, solar, suspension, water tanks, swivels and other road-tested van parts.
More in parts makers and kit makers; every build topic is on the DIY hub. The electrical series: the whole system, batteries, solar panels, charge controllers, DC-DC chargers, inverters, inverter chargers, shore power, battery monitors, wire size and fuse size.
More electrical guides: series vs parallel panels, flexible vs rigid panels, battery isolators and the power budget. The whole build order is in the DIY van build guide.
Questions people ask
What does a basic camper van wiring diagram include?
A house battery with a main fuse and switch, a positive and a negative busbar, a shunt on the battery negative, each charger (solar controller, DC-DC charger, shore charger) fused at the busbar, a fused 12 V fuse block for loads, and an inverter on its own fuse. Every line carries its wire size and fuse rating.
Where does the main fuse go in a van wiring diagram?
In the battery positive cable, as close to the terminal as you can. Samlex asks for its inverter's Class T fuse within 7 in of the battery positive, and Victron says a DC system should always have a main fuse, with each consumer fused after it.
Where does the shunt go?
On the battery negative, with nothing else on that side. Victron's SmartShunt manual says the battery negative goes alone to the BATTERY MINUS side and every load, inverter and charger negative to the other side, or it is left out of the state of charge.
Can I copy a wiring diagram from the internet?
Use one to learn the layout, then redraw it for your parts. Fuses and cables come from each part's manual and your own cable lengths, and a diagram drawn for one inverter or charger can be wrong for another. Ours lists the manual for every number.
Is a 24 V van wiring diagram different?
The layout is the same; the numbers halve. Two 12 V batteries go in series, the inverter draws about half the current (Samlex's 2,000 W model takes a 125 A fuse at 24 V against 250 A at 12 V), and 12 V loads need a 24 to 12 V converter.
How does shore power fit into the diagram?
Through a battery charger or an inverter charger, which then feeds the DC busbars like any other charger. The 120 V side from the inlet to the charger and outlets is a job for a licensed electrician, and Victron's guide puts an RCD (GFCI) in it.
What wire size do I need between the battery and the inverter?
The size the inverter manual gives for your length, checked against the fuse. Samlex lists 2/0 AWG at 6 ft for its PST-2000-12 with a 250 A fuse; 2/0 is rated 330 A at 105 °C, above the fuse, so it passes Victron's rule.
Do I need an electrician for the wiring diagram?
Not to draw it, but have a qualified person check it before you buy parts, and use a licensed electrician for anything at 120 V. Victron's wiring book recommends a qualified electrician or technician for electrical work.
Sources
Every fuse, cable and limit on the diagrams is from the named part's manual: Victron (MPPT 100/30, Orion XS, Orion-Tr, SmartShunt, Wiring Unlimited), Samlex (PST-2000) and Battle Born (BB10012), all opened on 25 November 2026. Where a manual gives no cable, the wire size is our calculation with the formula and 33 CFR 183.425 Table 5 values our wire size calculator uses, checked so the cable is rated at least as high as its fuse (Victron's rule), for example lengths we chose; those cells are marked. Inverter current uses Samlex's formula. The parts are examples from makers in our directory, not recommendations. ABYC E-11 and NFPA texts were not opened and are not quoted.
- Victron Energy, Wiring Unlimited, chapter 1: safety warnings and disclaimer. Read 25 November 2026
- Victron Energy, Wiring Unlimited, chapter 4: DC wiring (fuses, interrupt rating, isolation switches, shunt). Read 25 November 2026
- Victron Energy, Wiring Unlimited, chapter 7: Ground, earth and electrical safety. Read 25 November 2026
- Battle Born Batteries, BB10012 100Ah 12V LiFePO4 battery manual (revision 038, 12 August 2026). Read 25 November 2026. Specifications, series and parallel connection, fuses
- Victron Energy, SmartSolar MPPT 100/30 and 100/50 manual, Installation. Read 25 November 2026
- Victron Energy, Orion XS 12/12-50A DC-DC battery charger manual, Installation. Read 25 November 2026
- Victron Energy, Orion-Tr Smart DC-DC Charger Non-Isolated manual, Installation (cable and fuse table). Read 25 November 2026
- Victron Energy, Orion-Tr Smart DC-DC Charger Non-Isolated manual, Specifications (12/24-15 and 24/12-30). Read 25 November 2026
- Samlex America, PST-1500 and PST-2000 pure sine wave inverter owner's manual (July 2026), Table 8.3 and section 8.4.4. Read 25 November 2026
- Victron Energy, SmartShunt manual, Installation. Read 25 November 2026
- Victron Energy, SmartShunt manual, Configuration (charged voltage by system voltage). Read 25 November 2026
- Victron Energy, RV Shore Power: A beginner's guide (knowledge article, 16 June 2026). Read 25 November 2026
- US Coast Guard, 33 CFR 183.425, Table 5, Allowable Amperage of Conductors (eCFR); the ampacity column our wire calculator uses. Read 24 November 2026, as typed in our wire size data
- Ancor, Catalog 2024, page 62: circular mil voltage drop formula; the formula our wire calculator uses. Read 24 November 2026, as typed in our wire size data