Guides / RV water pump for a van: flow, amps, wiring and mounting
RV water pump for a van: flow, amps, wiring and mounting
The short answer
Last updated 25 November 2026
Key takeaways
- Match flow to the fixtures you run at once: a WaterSense faucet uses up to 1.5 and a showerhead up to 2 gallons a minute, so a 3.0 gallon a minute pump covers both.
- Published 12V pumps run from 1.4 gallons a minute at 2.0 amps at 10 psi (Flojet Triplex) to 5.0 gallons a minute on a 10 amp supply (Remco Aquajet ARV).
- Every maker we read requires a strainer on the inlet, and SHURflo and Flojet want flexible hose on both pump ports to keep vibration out of the plumbing.
- Give the pump its own fused circuit and a switch on the positive lead, sized to the maker's wire chart, and shut it off when you leave the van.
- By-pass pumps need no accumulator; plain pressure-switch pumps cycle less with one.
The pump is the only moving part in most van water systems. Choosing one is three questions: how much flow, how much current, and how it is mounted and wired. Where it sits in the whole system is in how to plumb a camper van water system.
12V diaphragm pump or manual pump?
A 12V diaphragm pump gives running water and shower pressure at the turn of a tap and draws a few amps while it runs. A hand or foot pump needs no wiring and wastes less water, but you pump every cup and there is no shower pressure.23
Demand pumps carry a pressure switch: the pump runs until the lines reach its shut-off pressure, stops, and starts again when a tap opens and the pressure falls. SEAFLO's FAQ describes it that way, and adds that a by-pass recirculates water inside the pump to smooth flow and cut cycling.5 Whale, made by Munster Simms in our directory, sells manual galley pumps; we could not open its own specification pages in this run, so we quote no foot pump figures rather than retailer numbers.
How much flow and pressure do you need?
Enough for the fixtures you run at once. WaterSense caps faucets at 1.5 and showerheads at 2 gallons a minute, so a faucet and shower together want 3.5. Published 12V pumps run from 1.4 to 5.0 gallons a minute.6734
Sources: Flojet, SHURflo and Remco published figures; WaterSense fixture maximums.32467
Copy the table to compare pumps. Every value is the maker's.
| Pump | Flow | Shut-off | Amps |
|---|---|---|---|
| Flojet R3426-500 Triplex3 | 1.4 GPM | 20 psi | 2 A, at 10 psi |
| SHURflo Trail King 7, 2095-204-1122 | 1.8 GPM | 20 psi | 3.5 A, maximum |
| SHURflo 4029-181-A542 | 2.0 GPM | 30 psi | 3.2 A, maximum |
| SHURflo Whisper King, 2095-243-4442 | 2.6 GPM | 45 psi | 4.5 A, maximum |
| SHURflo 4009-101-A652 | 3.0 GPM | 55 psi | 4.5 A, maximum |
| SHURflo 4009-101-A872 | 3.0 GPM | 45 psi | 5.3 A, maximum |
| Remco Aquajet 55AQUAJET-AES4 | 3.4 GPM | not stated | 6.5 A, supply the manual asks for |
| Remco Aquajet 55AQUAJET-ARV4 | 5.0 GPM | not stated | 10 A, supply the manual asks for |
Higher shut-off pressure is not always better. SHURflo's catalog sells the same 3.0 gallon 4009 at 20, 30, 45 and 55 psi, and the maximum current changes with it.2 Remco warns that its 5-chamber Aquajets are more powerful than most RV pumps and may draw more current than the pump they replace, so every wire, fuse and switch must be sized for it.4
How much power does a water pump use?
Very little per day, because it runs only while water flows. At its rated 3.0 gallons a minute, a SHURflo 4009-101-A65 moves 8 gallons in about 2.7 minutes; at its 4.5 amp maximum that is about 0.2 amp-hours, by our arithmetic.2
Sources: Flojet (at 10 psi), SHURflo catalog (maximum), Remco manual (supply the wiring must provide).324
Real flow is lower than the rating once the lines are under pressure, so double our figure for margin; even then a pump is one of the smallest loads in a van. Size the circuit for the maximum current, not the daily total: that is what the fuse and wire see. The battery side is in the van electrical guide.
How do you wire and fuse a water pump?
On its own fused circuit with a switch on the positive lead, using the wire size the maker gives for your length. Flojet says a 10 amp fuse; SHURflo says the fuse on the pump label and a 10 amp minimum circuit; Remco says 15 amps for its ARV.314
Each maker's instructions, as written. Copy the row for your pump.
| Pump | Wire | Fuse | Switch |
|---|---|---|---|
| SHURflo 4008 Revolution1 | 16 AWG minimum, 12 AWG recommended; 16 AWG to 25 ft, 14 to 50, 12 to 70, 10 to 110 ft, measured source to pump and back | Fuse or breaker specified on the pump label; 10 A minimum circuit | 15 A switch on the positive (red) lead |
| Flojet R3426-5003 | 14 gauge stranded to 20 ft, 12 gauge to 50 ft, from the power source | 10 A fuse on the positive lead | 10 to 15 A on-off switch on the positive lead |
| Remco Aquajet AES4 | Existing wiring must supply 6.5 A without excessive voltage drop | 10 A AGC fuse in the supplied holder | 10 or 15 A rated controller, or add a 30 A relay |
| Remco Aquajet ARV4 | Must supply 10 A: 14 AWG to 10 ft, 12 AWG to 20 ft, 10 AWG beyond | 15 A AGC fuse in the supplied holder | 10 or 15 A rated controller, or add a 30 A relay |
The makers measure length differently: SHURflo's chart counts from the power source to the pump and back to ground, at 10% voltage drop on a 15 amp circuit; Flojet and Remco give distances without saying round trip.134 When unsure, use the heavier wire. SHURflo warns that undersized wire lowers performance and can create a fire hazard, and says to shut off power to the pump when you leave the vehicle.1 Remco's pumps carry an automatically resetting thermal protector, so a stopped pump may restart at any time.4 General fusing is in what size fuse you need and the wire size chart.
How do you mount a water pump?
Near the tank, on a solid surface, with a strainer on the inlet and flexible hose on both ports. SHURflo says within 6 feet of the tank, in at least 1 cubic foot of space, and at least 18 inches of 1/2 inch hose on each port.1
Drawn by vanlife.co from SHURflo's and Flojet's installation rules. Blue is water, dashed is flexible hose, red is the fused positive lead. Not to scale.13
- Strainer. SHURflo requires at least a 50-mesh strainer; Flojet says its strainer or an equivalent is required for the warranty; Remco calls a screen filter necessary; SEAFLO says to use the one supplied, or the diaphragm can be punctured.1345
- Hose, not rigid pipe, at the pump. SHURflo says not to connect the ports or strainer to plastic or rigid pipe, because the pump's motion carries through as noise and can crack components; Flojet asks for 1/2 inch flexible hose, braided or reinforced, that will not collapse under suction.13
- Position. SHURflo pumps can mount in any position; Flojet mounts horizontally or vertically with the pump head down; SEAFLO prefers horizontal, and pump head down if vertical, so water cannot run into the motor.135
- Suction lift. Flojet's Triplex self-primes up to 9 feet, SHURflo's 2095 series lifts up to 8 feet, and SEAFLO lists 4 feet for its 21 series. A pump close to and below the tank works least.325
- Thread sealant. SHURflo says its 1/2 inch male ports seal with swivel barb fittings hand-tightened, and that sealer or Teflon tape can crack housings or stop the valves working.1
Do you need an accumulator?
Not with a by-pass pump. SHURflo says its 4008 Revolution needs none; Flojet says its Triplex reduces the need. With a plain pressure-switch pump, an accumulator downstream cuts cycling and pulsation; charge it to the pump's restart pressure.132
SHURflo's 4008 by-pass starts to open at about 40 psi and reaches full by-pass at about 62 psi, with the pressure switch set to shut off at 55; the manual says only a technician with gauges should adjust either setting, because if they overlap the pump will not shut off.1 SEAFLO gives the same warning for its by-pass pumps.5 SHURflo's accumulators are a 24 ounce nylon tank pre-charged to 30 or 20 psi and rated to 125 psi, and a 2 gallon stainless tank pre-charged to 20 psi; the catalog says they reduce cycling, pulsation and pressure spikes and save battery power.2 Remco's troubleshooting list suggests a pulsation dampener for hydraulic pulsation in its Aquajets.4
Can a pump run dry, and for how long?
It depends on the pump. Flojet says its Triplex runs dry without damage but not to run it more than 15 minutes at a time; SEAFLO says its 21 series can run dry for about 3 minutes and does not stop by itself when the tank empties.35
SHURflo calls its 4008 an intermittent duty pump and says continuous high-pressure use, such as running a reverse osmosis filter, shortens its life and is not covered by warranty.1 SEAFLO puts its 21 series motor life at about 600 hours and its diaphragm at about 1,000 hours.5 A pump that hums with no water flowing is wearing; switch it off and find out why.
Why does a water pump cycle or not prime?
Cycling with no tap open means pressure is leaking away: a fitting, a valve or toilet, or air in the water heater. No prime usually means an air leak on the suction side, a clogged strainer or an empty tank, by the makers' troubleshooting lists.13
| Symptom | What the manuals say to check |
|---|---|
| Runs with every tap closed | Leaks on the outlet side, leaky valves or toilet, air trapped in the water heater, low voltage, a punctured diaphragm.13 |
| Rapid cycling at a tap | Restrictive faucets or shower heads; a filter that should be on a separate feed line; shut-off set too low.1 |
| Runs but will not prime | Clogged strainer, empty tank, an air leak on the inlet, kinked or restricted hose, debris in the valves.13 |
| Noisy | Rigid pipe at the ports, a mounting surface that drums, loose feet, air in the lines, a restricted inlet.1 |
| Pulsing flow | Restricted or undersized discharge lines, fittings or valves.3 |
SHURflo adds that driving vibration loosens plumbing, strainers and pump hardware, and that a lack of sanitizing is the number one reason for early pump failure, because scale builds up on the diaphragm and valves.1 Draining the pump before freezing weather is in how to winterize a van water system, and keeping a filter off the pump's main line is in the van water filter guide.
Who sells water pumps in our directory?
These 4 verified businesses make or sell pumps, tanks and plumbing parts; each links to its directory listing.
- Munster Simms Engineering Ltd., Bangor, Northern Ireland, United Kingdom: Makes Whale water pumps, plumbing, taps, sockets and heating systems for campervans, caravans and motorhomes, plus marine water systems.
- Go Code Overland, Bargersville, Indiana: Bargersville, Indiana maker of interior trim kits, water tanks, showers, water heaters and hardware for Sprinter, Transit and ProMaster van builds.
- Vanlife Outfitters, Sarasota, Florida: Sarasota, Florida store for camper van electrical systems, batteries, solar, suspension, water tanks, swivels and other road-tested van parts.
- Camco, Greensboro, North Carolina: Greensboro, North Carolina maker of aftermarket parts and accessories for the RV and outdoor recreation market, since 1966.
More on the parts page and the kits page; every build guide is on the DIY hub. The rest of the water cluster: van water system, fresh water tank, grey water, water filter, winterizing and toilets.
More water guides: water heaters and showers. The whole build order is in the DIY van build guide.
Questions people ask
What size water pump does a camper van need?
Enough flow for the fixtures you run at once. A WaterSense faucet flows at most 1.5 gallons a minute and a WaterSense showerhead 2.0, so a 3.0 gallon a minute pump such as SHURflo's 4009 covers both, at 4.5 to 5.3 amps maximum.
How many amps does an RV water pump draw?
From about 2 to 10 amps on 12V. Flojet lists 2.0 amps at 10 psi for its 1.4 gallon a minute Triplex, SHURflo 2.8 to 5.3 amps maximum for its 2.0 to 3.0 gallon pumps, and Remco asks for a 10 amp supply for its 5.0 gallon Aquajet ARV.
Do I need an accumulator with my water pump?
Not with a by-pass pump: SHURflo says its 4008 Revolution needs none, and Flojet says its Triplex reduces the need. With a plain pressure-switch pump, an accumulator downstream cuts cycling and pulsation; SHURflo says to charge it to the pump's restart pressure.
Why does my RV water pump keep turning on with no tap open?
The manuals point to a leak on the pressure side, a leaking valve or toilet, air trapped in the water heater, or debris holding the pump valves open. Check fittings first; driving vibration loosens them, as SHURflo notes.
Does a 12V water pump need a strainer?
Yes. SHURflo requires a 50-mesh strainer on the inlet, Flojet says its strainer or an equivalent is required for the warranty, Remco says a screen filter is necessary, and SEAFLO says to use the strainer supplied with the pump.
Can a water pump run dry?
Some for a while. Flojet says its Triplex can run dry without damage but not to run it more than 15 minutes continuously when draining; SEAFLO says its 21 series can run dry for about 3 minutes and will not stop by itself when the tank empties.
Where should the water pump go in a van?
Close to the tank, on a solid surface, where you can reach the strainer. SHURflo says within 6 feet of the tank and in at least 1 cubic foot of space for ventilation; it can mount in any position.
Is a foot pump or hand pump better than an electric pump?
A manual pump needs no wiring and uses no battery, but you pump every cup and there is no pressure for a shower. We could not open Whale's own specification pages in this run, so we quote no figures for foot pumps.
Sources
Pump flow, pressure, amps, wiring and installation rules are the makers' published figures: SHURflo's 4008 manual and EMEA RV catalog (12V models), Flojet's R3426-500 manual, Remco's Aquajet manual as hosted by Newmar, and SEAFLO's own pump FAQ. Fixture flows are EPA WaterSense maximums. Energy per day is our arithmetic, labeled. We could not open Whale's specification pages, so no foot pump figures appear. Read 25 November 2026.
- Pentair SHURflo, 4008 RV Revolution By-Pass Pump Installation and Operation Manual, 911-1008 Rev. K (PDF, as hosted by an RV dealer). Read 25 November 2026
- Pentair SHURflo, RV catalog (EMEA edition, PDF): 4029, 4009 and 2095 pumps, accumulators and strainers. Read 25 November 2026
- Xylem Flojet, R3426-500 Triplex Diaphragm Automatic Water System Pump instruction manual (PDF). Read 25 November 2026
- Remco Industries, Aquajet RV Water System Pumps User's Manual and Installation Guide, 55AQUAJET-AES, OES, ARV, ORV (PDF, as hosted by Newmar). Read 25 November 2026
- SEAFLO, Diaphragm pump F.A.Q.'s. Read 25 November 2026
- US EPA WaterSense, Bathroom sink faucets. Read 25 November 2026
- US EPA WaterSense, Showerheads. Read 25 November 2026