The short answer

Build 12 V for most camper vans. The alternator, fridge, fan, lights and pump are 12 V, and Victron says a campervan's short cable runs keep even a 3,000 W inverter manageable at 12 V. Choose 24 V when the inverter is over 3,000 VA, the cable runs are long or the array outgrows the controller, and budget for the converters it adds.

Last updated 25 November 2026

Key takeaways

  • Build 12 V unless something pushes you up: Victron says even a 3,000 W inverter and 900 W of solar are manageable at 12 V in a campervan, where cable runs are short.
  • 24 V halves the current for the same power: Victron's 2,400 W example draws 200 A at 12 V and 100 A at 24 V, and the cable loss falls from 5% to 1.3%.
  • Victron's preferred inverter limits are up to 3,000 VA at 12 V, up to 5,000 VA at 24 V, and 48 V above that.
  • A 24 V van adds a 12/24 DC-DC charger for the alternator and a 24/12 converter, or 24 V versions, for the 12 V fridge, fan, lights and pump.
  • For a 24 V lithium bank Victron recommends a 24 V battery over two 12 V batteries in series; Battle Born allows series up to 48 V. Follow your battery's manual.

System voltage is the first decision on how to wire a camper van; both versions are drawn on the van wiring diagram, and the cable sizes come from the wire size calculator.

What changes when a van system runs at 24V instead of 12V?

The current halves for the same power, so cables, fuses, busbars and switches can be smaller and lose less. In Victron's example a 2,400 W load draws 200 A at 12 V, 100 A at 24 V and 50 A at 48 V.4

Same load, three voltagesCurrent and cable loss for 2,400 W on the same two cables
12 V systemcable loss 0.64 V, 5%
200 A
24 V systemcable loss 0.32 V, 1.3%
100 A
48 V systemcable loss 0.16 V, 0.3%
50 A

Source: Victron Energy, Wiring Unlimited, section 2.7, read 25 November 2026; chart ours.4

Power is volts times amps, so doubling the voltage halves the amps for the same watts.4 Victron's RV article puts it in parts: a 3,000 W inverter charger can pull 4,500 W at peak, 375 A at 12 V, which calls for wire, fuses, busbars and switches rated to 400 A; at 24 V the same peak is 187.5 A, and 200 A parts do.1 What does not change is the energy: two 12 V 100 Ah batteries store 2,400 Wh whether wired as 12 V 200 Ah or 24 V 100 Ah.1

When does 24V or 48V make sense in a van?

When the inverter is over 3,000 VA, when heavy cable runs are long, or when the solar array outgrows the controller at 12 V. Victron's preferred inverter limits are up to 3,000 VA at 12 V, up to 5,000 VA at 24 V and 48 V above that.51

Victron's preferred inverter size by system voltageWhere each system voltage fits
0 VA2,000 VA4,000 VA6,000 VA8,000 VA
12 Vup to 3,000 VA
12 V
24 Vup to 5,000 VA
24 V
48 V5,000 VA and up
48 V

Source: Victron Wiring Unlimited, section 4.1, and Victron's batteries in series or parallel article, read 25 November 2026; the 8,000 VA end of the axis is ours. Chart ours.51

Victron's own advice for vans is plain: 24 V pays off where high current meets long wire runs; in a campervan the runs are short, so even systems built around a 3,000 W inverter and a 900 W array are manageable at 12 V; and trucks and boats with long runs and 24 V alternators are where 24 V makes more sense.1 Its inverter guide describes 12 V as typical for smaller systems with short runs and mostly 12 V appliances, 24 V for medium systems, and 48 V for high-power systems where current and cable size matter most.3 The book adds that if a few loads or chargers can only work at 12 V, DC-DC converters are an alternative to running the whole system at 12 V.5

Solar is the other trigger. Victron's SmartSolar MPPT 100/30 is rated 440 W of nominal PV at 12 V and 880 W at 24 V,9 so a 750 W array needs either a bigger controller or the same one on a 24 V bank, as Victron's article works through.1

How much smaller is the wire at 24V?

Two or three gauge sizes. Our calculator gives a 2,000 W load 6 ft from the battery 2 AWG at 12 V, 6 AWG at 24 V and 12 AWG at 48 V. Samlex's 2,000 W inverter drops from 2/0 to 4 AWG at 6 ft.81716

Wire size for the same load at 12, 24 and 48 V (3% drop, 105 °C copper; copy it)
Load and one-way length12 V24 V48 V
2,000 W inverter, 6 ft run166.7 A: 2 AWGset by drop and ampacity83.3 A: 6 AWGset by ampacity41.7 A: 12 AWGset by ampacity
3,000 W inverter, 6 ft run250 A: 1/0 AWGset by drop and ampacity125 A: 4 AWGset by ampacity62.5 A: 8 AWGset by ampacity
1,200 W load, 10 ft run100 A: 2 AWGset by voltage drop50 A: 8 AWGset by voltage drop25 A: 14 AWGset by voltage drop

Our sizing: current is watts divided by volts (no inverter losses), Ancor's circular mil formula at 3% drop and 33 CFR 183.425 Table 5 ampacity at 105 °C, the same data as our wire calculator. Loads and lengths are examples; the fuse must still not exceed the cable, and a part's manual overrides this table.17165

Inverter at 12 V and 24 VBattery current and fuse for a 2,000 W inverter
Current at 12 VPST-2000-12
196 A
Current at 24 VPST-2000-24
95 A
Fuse at 12 V2/0 AWG at 6 ft
250 A
Fuse at 24 V4 AWG at 6 ft
125 A

Formula (watts / volts x 85% at 12 V, 88% at 24 V), fuses and cables from Samlex's PST manual, read 25 November 2026; arithmetic and chart ours.8

Small circuits gain little: a fan or a light string draws a few amps either way, and its wire is set by the smallest gauge you would use anyway. Busbars follow the cables, because Victron's RV article sizes them like wire;1 on 24 V the same branches carry half the current, so our reading is that the busbar check in busbar sizing often passes one size smaller. Run the check for your own fuses.

Which parts change on a 24V van, and which 12V loads need a converter?

The battery, alternator charger, inverter and every 12 V load. Victron lists a 12/24 DC-DC charger for the alternator and a 24/12 converter for 12 V appliances, and notes most van fridges, lights and fans are 12 V, with 24 V versions dearer and harder to find.1

Our drawing. Parts and ratings from the Orion-Tr and MPPT manuals and Victron's series or parallel article. On a phone, scroll the drawing sideways.119101

Part by part: 12 V van against 24 V van (copy it)
Part12 V van24 V van
House battery12 V batteries in parallelA 24 V battery, or 12 V batteries in series. Battle Born allows series up to 48 V; Victron cautions against series lithium and prefers a 24 V battery.71
Alternator charging12/12 DC-DC charger12/24 DC-DC charger: Victron's Orion-Tr 12/24-15 gives 15 A at 24 V from an 8 to 17 V input.111
12 V loads (fridge, fan, lights, pump)Straight from the fuse blockThrough a 24/12 converter, such as Victron's Orion-Tr 24/12-30 (30 A at 12 V) or REDARC's DPS1240 (40 A at 12 V from 9 to 32 V in), or buy 24 V versions.11131
Solar controllerVictron MPPT 100/30: 440 W nominal PVThe same controller: 880 W nominal PV, twice the array.9
InverterSamlex PST-2000-12: 250 A Class T fuse, 2/0 AWG at 6 ftSamlex PST-2000-24: 125 A fuse, 4 AWG at 6 ft8
USB chargingScanstrut SC-USB-03: 36 W maxThe same socket: 60 W max, enough to fast-charge a laptop.14
LED dimmerArmacost ProLine: up to 96 W of 12 V LEDsThe same dimmer: up to 192 W of 24 V LEDs15
Fuses and switchesMost DC fuses are rated for 12 VMost DC fuses suit 24 V too; at 48 V check each one, as Victron says many are not rated for it.5

Size the converter for every 12 V load that can run at once, then fuse it on both sides. Victron's non-isolated Orion-Tr table puts a 60 A fuse on a 12 V side and a 30 A fuse on a 24 V side.12 REDARC's DPS1240 asks for a 60 A input fuse and a 60 A output fuse, recommends bolt-down MIDI fuses over blade fuses, and advises against self-resetting breakers that can trip early; it also says not to use the DPS to charge batteries.13 Some 12 V parts take 24 V directly: Scanstrut's SC-USB-03 runs from 10 to 32 V and Armacost's dimmer from 12 or 24 V, but the LEDs it dims must match the supply.1415 Read each label before you wire a 24 V circuit to it.

24V battery or two 12V batteries in series?

Victron recommends a 24 V lithium battery, cautioning that 12 V batteries in series can drift out of balance. Battle Born says its 12 V BB10012 can be wired in series up to 48 V. Follow your battery's manual and its balancing rules.17

Victron's reason: batteries in series get the same current but can see slightly different voltages, so their state of charge drifts; each must be charged and balanced before joining, and then a balancer or BMS has to keep them matched. With 24 V and 48 V lithium batteries widely available, it cautions against series lithium.1 Battle Born's manual lists series connection up to 48 V and gives 24 V charge settings, and our wiring diagram uses two of them in series for its 24 V variant on that basis.7 Battle Born also says never to operate its battery in series or parallel with any other type of battery.7 More in lithium batteries for a van.

Is 24V or 48V more dangerous?

The shock risk grows with voltage: Victron notes people have died from voltages as low as 42 V. And fuses, breakers and switches must be rated for the system's DC voltage; Victron says most DC fuses suit 12 and 24 V but not necessarily 48 V.65

Victron's book also warns that DC breakers may not be unidirectional, so their wiring direction matters, and that some fuses rated for both AC and DC carry a lower DC voltage rating.5 Its own 275 A battery switch is rated to switch 12, 24 and 48 V.5 At 24 V the parts market is still deep; at 48 V check every fuse and switch label before you buy. The fuse rules on fuse size apply at any voltage, and the 120 V side of an inverter stays a licensed electrician's work whatever the battery voltage.

How do you decide? A six-question checklist

Answer six questions about the inverter, cable runs, solar, loads, alternator and batteries. If most point to 12 V, build 12 V; if the inverter or array alone forces 24 V, take it and add the converters.

12 V or 24 V decision checklist (copy it)
#QuestionWhich way it leans
1Will the inverter be over 3,000 VA?Yes points to 24 V; over 5,000 VA, 48 V (Victron's preferred limits).5
2Are your heavy cable runs long (a big van, a battery far from the inverter)?Yes points to 24 V. Victron: higher voltage pays where high current meets long runs.1
3Is the array bigger than your controller can take at 12 V?Yes points to 24 V: the MPPT 100/30 doubles from 440 to 880 W.9
4Are most loads 12 V (fridge, fan, lights, pump, USB)?Yes points to 12 V; on 24 V each needs a converter or a 24 V version.1
5Is the van's alternator 12 V?Yes points to 12 V; a 24 V bank needs a 12/24 DC-DC charger.111
6Do you want to use two 12 V lithium batteries in series?Victron advises a 24 V battery instead; Battle Born allows series to 48 V. Read your battery's manual.17

Who makes 12V and 24V van parts?

These 5 verified businesses in our directory make batteries, chargers, converters or inverters in 12 V and 24 V versions; each links to its listing.

  • Victron Energy B.V., Almere, Netherlands: Maker of off-grid energy equipment such as inverters, chargers, batteries, battery monitors and solar charge controllers, used in vans, boats and buildings.
  • Battle Born, Reno, Nevada: Sells LiFePO4 lithium batteries, solar gear, inverters and power components for RV, trucking, marine and off-grid use from Reno, Nevada.
  • Lithionics Battery, Clearwater, Florida: Lithium battery and power system maker for RVs, camper vans, boats and fleets, owned by Winnebago Industries since 2023.
  • REDARC Electronics, Grapevine, Texas: Makes automotive electronics including dual battery chargers, complete van and overlanding power kits, inverters, solar panels and towing brake controllers.
  • Samlex America, Burnaby, British Columbia, Canada: Maker of power inverters, inverter chargers, battery chargers, DC-DC converters and Samlex Solar products for RV, marine and off-road use.

More in parts makers and kit makers; every build topic is on the DIY hub. The electrical series: the whole system, wiring diagram, busbars, batteries, battery monitors, solar panels, charge controllers, DC-DC chargers, inverters, inverter chargers, shore power, lights and switches, wire size and fuse size. Safety: fire safety, CO alarms and propane.

Questions people ask

Is 12V or 24V better for a camper van?

12 V for most vans. Victron says campervan wire runs are short enough that even a 3,000 W inverter and a 900 W array are manageable at 12 V, and that 12 V matches the alternator, fridges, lights and fans. 24 V pays off with a bigger inverter or long cable runs.

Does 24V save money in a van?

Sometimes on cable, fuses and the solar controller, rarely overall. Victron says the gains are offset by a 12/24 DC-DC charger for the alternator and a 24/12 converter for 12 V appliances, and that 24 V fridges, lights and fans cost more and are harder to find.

How much smaller is the wire at 24V?

Half the current, so often two or three gauge sizes. In our wire calculator, a 2,000 W load 6 ft from the battery needs 2 AWG at 12 V and 6 AWG at 24 V at a 3% drop; Samlex's own table drops from 2/0 to 4 AWG for its 2,000 W inverter at 6 ft.

Can I run 12V appliances on a 24V battery?

Only through a 24 to 12 V converter, or with a 24 V version of the appliance. Victron's Orion-Tr 24/12-30 gives 30 A at 12 V; REDARC's DPS1240 gives 40 A at 12 V from a 9 to 32 V input. Size the converter for all your 12 V loads at once.

Can I make 24V from two 12V lithium batteries?

Battle Born says its BB10012 can be wired in series up to 48 V. Victron cautions against series lithium because the batteries can drift out of balance, and recommends a 24 V lithium battery instead. Follow your own battery's manual and charge each battery full before joining them.

When does 48V make sense in a van?

Rarely. Victron's preferred inverter limits are up to 3,000 VA at 12 V, up to 5,000 VA at 24 V, and 48 V from 5,000 VA. Victron also notes many DC fuses are not rated for 48 V, and that people have died from voltages as low as 42 V.

Does the alternator charge a 24V house battery?

Through a 12/24 DC-DC charger. Victron's Orion-Tr 12/24-15 takes 8 to 17 V in and gives 15 A at 24 V; its cable table puts a 60 A fuse on the 12 V side and a 30 A fuse on the 24 V side.

Sources

Rules and limits are from Victron's Wiring Unlimited book, its RV knowledge articles and its inverter guide; part figures are from the Samlex, Victron (MPPT, Orion-Tr), REDARC, Scanstrut, Armacost and Battle Born manuals and product pages, all opened 25 November 2026. Wire sizes in the comparison table are our calculation with the formula and 33 CFR 183.425 Table 5 values our wire size calculator uses (3% drop, 105 °C copper), for example loads we chose; inverter current uses Samlex's formula. No prices are given: no maker page we opened compared 12 V and 24 V prices.

  1. Victron Energy, Batteries in series or parallel: which is right for your system? (knowledge article, 23 October 2026). Read 25 November 2026
  2. Victron Energy, RV electrical system components (knowledge article, 3 September 2026). Read 25 November 2026
  3. Victron Energy, Inverter/charger help me choose, section 3.2 Battery voltage. Read 25 November 2026
  4. Victron Energy, Wiring Unlimited, chapter 2: Theory (the 2,400 W example at 12, 24 and 48 V). Read 25 November 2026
  5. Victron Energy, Wiring Unlimited, chapter 4: DC wiring (preferred inverter size per system voltage, fuse voltage ratings, switches). Read 25 November 2026
  6. Victron Energy, Wiring Unlimited, chapter 1: safety warnings. Read 25 November 2026
  7. Battle Born Batteries, BB10012 100Ah 12V LiFePO4 battery manual (revision 038, 12 August 2026). Read 25 November 2026. Series to 48 V, parallel
  8. Samlex America, PST-1500 and PST-2000 pure sine wave inverter owner's manual (July 2026), Table 8.3 and the DC current formula. Read 25 November 2026
  9. Victron Energy, SmartSolar MPPT 100/30 and 100/50 manual, Technical specifications (nominal PV power at 12 and 24 V). Read 25 November 2026
  10. Victron Energy, SmartSolar MPPT 100/30 and 100/50 manual, Installation (72 cells in series for a 24 V battery). Read 25 November 2026
  11. Victron Energy, Orion-Tr Smart DC-DC Charger Non-Isolated manual, Specifications. Read 25 November 2026
  12. Victron Energy, Orion-Tr Smart DC-DC Charger Non-Isolated manual, Installation (cable and fuse recommendations). Read 25 November 2026
  13. REDARC, In-vehicle DC Power Supply DPS1225, DPS1240, DPS2410 and DPS2420 instruction manual. Read 25 November 2026
  14. Scanstrut, ROKK Charge Pro SC-USB-03 (RV product page and specifications). Read 25 November 2026
  15. Armacost Lighting, ProLine Rotary Knob LED Dimmer, item 511129, installation sheet. Read 25 November 2026
  16. US Coast Guard, 33 CFR 183.425, Table 5, Allowable Amperage of Conductors (eCFR); the ampacity column our wire calculator uses. Read 24 November 2026, as typed in our wire size data
  17. Ancor, Catalog 2024, page 62: circular mil voltage drop formula; the formula our wire calculator uses. Read 25 November 2026